First Results With Wavefront-guided Photorefractive Keratectomy for Hyperopia
Zoltán Zsolt Nagy, Ilona Palágyi-Deák, Andrea Kovács, Edit Kelemen, W Förster
Abstract
Zoltán Zsolt Nagy, Ilona Palágyi-Deák, Andrea Kovács, Edit Kelemen, W Förster
Abstract
PURPOSE: To compare the results of traditional laser photoablation and wavefront-supported customized ablation (WASCA) in hyperopic photorefractive keratectomy (H-PRK). METHODS: This was a prospective study, comparing two treatment groups, each comprising 40 eyes of 20 patients. Wavefront aberrations were examined using a Shack-Hartmann aberrometer. Preoperative refraction was similar in the two groups; in the traditional H-PRK group (Group 1) it was +3.10 +/- 0.85 D, and in the WASCA-guided group (Group 2) it was +2.90 +/- 0.80 D. H-PRK was performed with the Asclepion-Meditec MEL 70 flying-spot excimer laser. The follow-up time was 6 months. RESULTS: In Group 1, mean postoperative refraction was +0.14 +/- 0.24 D, and in Group 2, -0.10 +/- 0.25 D; mean uncorrected visual acuity was 0.92 +/- 0.16 in Group 1 and 0.95 +/- 0.18 in Group 2. Mean best spectacle-corrected visual acuity was 0.96 +/- 0.04 in Group 1 and 1.06 +/- 0.13 in Group 2. In Group 1, 67.5% (27 of 40 eyes), and in Group 2, 85% (34 of 40 eyes) were within +/-0.50 D of target refraction. Regarding change of spectacle-corrected visual acuity in Group 1, 5% (2 of 40 eyes), and in Group 2, 20% (8 of 40 eyes) gained one Snellen line compared to the preoperative; in Group 1, 10% (4 of 40 eyes), and in Group 2, 12.5% (5 of 40 eyes) lost two Snellen lines. In Group 2, the root mean square value for the higher order aberration increased from the initial 0.134 to 0.257 microm at 6 months after surgery. CONCLUSIONS: WASCA-guided hyperopic-PRK treatment was found to be safe and predictable. The results were better than those achieved with traditional PRK performed using the same flying-spot type excimer laser.
OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
PURPOSE: To compare the results of traditional laser photoablation and wavefront-supported customized ablation (WASCA) in hyperopic photorefractive keratectomy (H-PRK). METHODS: This was a prospective study, comparing two treatment groups, each comprising 40 eyes of 20 patients. Wavefront aberrations were examined using a Shack-Hartmann aberrometer. Preoperative refraction was similar in the two groups; in the traditional H-PRK group (Group 1) it was +3.10 +/- 0.85 D, and in the WASCA-guided group (Group 2) it was +2.90 +/- 0.80 D. H-PRK was performed with the Asclepion-Meditec MEL 70 flying-spot excimer laser. The follow-up time was 6 months. RESULTS: In Group 1, mean postoperative refraction was +0.14 +/- 0.24 D, and in Group 2, -0.10 +/- 0.25 D; mean uncorrected visual acuity was 0.92 +/- 0.16 in Group 1 and 0.95 +/- 0.18 in Group 2. Mean best spectacle-corrected visual acuity was 0.96 +/- 0.04 in Group 1 and 1.06 +/- 0.13 in Group 2. In Group 1, 67.5% (27 of 40 eyes), and in Group 2, 85% (34 of 40 eyes) were within +/-0.50 D of target refraction. Regarding change of spectacle-corrected visual acuity in Group 1, 5% (2 of 40 eyes), and in Group 2, 20% (8 of 40 eyes) gained one Snellen line compared to the preoperative; in Group 1, 10% (4 of 40 eyes), and in Group 2, 12.5% (5 of 40 eyes) lost two Snellen lines. In Group 2, the root mean square value for the higher order aberration increased from the initial 0.134 to 0.257 microm at 6 months after surgery. CONCLUSIONS: WASCA-guided hyperopic-PRK treatment was found to be safe and predictable. The results were better than those achieved with traditional PRK performed using the same flying-spot type excimer laser.
Key concepts: Photoablation, Photorefractive keratectomy, Medicine, Ophthalmology, Visual acuity, Refractive error, Astigmatism, Excimer laser