2000NeurosurgeryRequires access

Brain Tumor Surgery with the Toronto Open Magnetic Resonance Imaging System: Preliminary Results for 36 Patients and Analysis of Advantages, Disadvantages, and Future Prospects

Mark Bernstein, Abdul Rahman Al-Anazi, Walter Kucharczyk, Pirjo Manninen, Michael Bronskill, Mark Henkelman

Open publisher page 92 citations

Abstract

OBJECTIVE: Frameless navigation systems represent a huge step forward in the surgical treatment of intracranial pathological conditions but lack the ability to provide real-time imaging feedback for assessment of postoperative results, such as catheter positions and the extent of tumor resections. An open magnetic resonance imaging system for intracranial surgery was developed in Toronto, by a multidisciplinary team, to provide real-time intraoperative imaging. METHODS: The preliminary experience with a 0.2-T, vertical-gap, magnetic resonance imaging system for intraoperative imaging, which was developed at the University of Toronto for the surgical treatment of patients with intracranial lesions, is described. The system is known as the image-guided minimally invasive therapy unit. RESULTS: Between February 1998 and March 1999, 36 procedures were performed, including 21 tumor resections, 12 biopsies, 1 transsphenoidal endoscopic resection, and 2 catheter placements for Ommaya reservoirs. Three complications were observed. All biopsies were successful, and the surgical goals were achieved for all resections. Problems included restricted access resulting from the confines of the magnet and the imaging coil design, difficulties in working in an operating room that is less spacious and familiar, inconsistent image quality, and a lack of nonmagnetic tools that are as effective as standard neurosurgical tools. Advantages included real-time imaging to facilitate surgical planning, to confirm entry into lesions, and to assess the extent of resection and intraoperative and immediate postoperative imaging to confirm the extent of resections, catheter placement, and the absence of postoperative complications. CONCLUSION: Intraoperative magnetic resonance imaging has great potential as an aid for intracranial surgery, but a number of logistic problems require resolution.

About this research paper

What this paper is about

OBJECTIVE: Frameless navigation systems represent a huge step forward in the surgical treatment of intracranial pathological conditions but lack the ability to provide real-time imaging feedback for assessment of postoperative results, such as catheter positions and the extent of tumor resections. An open magnetic resonance imaging system for intracranial surgery was developed in Toronto, by a multidisciplinary team, to provide real-time intraoperative imaging. METHODS: The preliminary experience with a 0.2-T, vertical-gap, magnetic resonance imaging system for intraoperative imaging, which was developed at the University of Toronto for the surgical treatment of patients with intracranial lesions, is described. The system is known as the image-guided minimally invasive therapy unit. RESULTS: Between February 1998 and March 1999, 36 procedures were performed, including 21 tumor resections, 12 biopsies, 1 transsphenoidal endoscopic resection, and 2 catheter placements for Ommaya reservoirs. Three complications were observed. All biopsies were successful, and the surgical goals were achieved for all resections. Problems included restricted access resulting from the confines of the magnet and the imaging coil design, difficulties in working in an operating room that is less spacious and familiar, inconsistent image quality, and a lack of nonmagnetic tools that are as effective as standard neurosurgical tools. Advantages included real-time imaging to facilitate surgical planning, to confirm entry into lesions, and to assess the extent of resection and intraoperative and immediate postoperative imaging to confirm the extent of resections, catheter placement, and the absence of postoperative complications. CONCLUSION: Intraoperative magnetic resonance imaging has great potential as an aid for intracranial surgery, but a number of logistic problems require resolution.

Why it matters

OpenAlex reports 92 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: Frameless navigation systems represent a huge step forward in the surgical treatment of intracranial pathological conditions but lack the ability to provide real-time imaging feedback for assessment of postoperative results, such as catheter positions and the extent of tumor resections. An open magnetic resonance imaging system for intracranial surgery was developed in Toronto, by a multidisciplinary team, to provide real-time intraoperative imaging. METHODS: The preliminary experience with a 0.2-T, vertical-gap, magnetic resonance imaging system for intraoperative imaging, which was developed at the University of Toronto for the surgical treatment of patients with intracranial lesions, is described. The system is known as the image-guided minimally invasive therapy unit. RESULTS: Between February 1998 and March 1999, 36 procedures were performed, including 21 tumor resections, 12 biopsies, 1 transsphenoidal endoscopic resection, and 2 catheter placements for Ommaya reservoirs. Three complications were observed. All biopsies were successful, and the surgical goals were achieved for all resections. Problems included restricted access resulting from the confines of the magnet and the imaging coil design, difficulties in working in an operating room that is less spacious and familiar, inconsistent image quality, and a lack of nonmagnetic tools that are as effective as standard neurosurgical tools. Advantages included real-time imaging to facilitate surgical planning, to confirm entry into lesions, and to assess the extent of resection and intraoperative and immediate postoperative imaging to confirm the extent of resections, catheter placement, and the absence of postoperative complications. CONCLUSION: Intraoperative magnetic resonance imaging has great potential as an aid for intracranial surgery, but a number of logistic problems require resolution.

Key concepts: Medicine, Magnetic resonance imaging, Intraoperative MRI, Neuronavigation, Interventional magnetic resonance imaging, Surgical planning, Catheter, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Brain Tumor Surgery with the Toronto Open Magnetic Resonance Imaging System: Preliminary Results for 36 Patients and Analysis of Advantages, Disadvantages, and Future Prospects — Research Paper | ScholarLens