A 500-kV Circuit Breaker Using SF6 Gas

R. C. Van Sickle, R. N. Yeckley

Open publisher page 9 citations

Abstract

The first 500-kV 35 000-MVA breakers to go in service in the United States have been developed and subjected to extensive testing. They are built of modules which can be combined for voltages of 345 kV, 500 kV, and 700 kV. The interrupting medium is SF6 gas in a completely sealed 2-pressure system, operating at constant densities. At 75°F, the higher pressure is about 240 psi; the lower is 45 psi. Contacts and blast valves of each pole unit are connected by a mechanical linkage operated by a pneumatic mechanism. The first breakers, using a mechanism designed for other breakers, have an interrupting time of 3 cycles. A special mechanism, designied for the new SF6 breakers, gives them an interrupting time of 2 cycles.

About this research paper

What this paper is about

The first 500-kV 35 000-MVA breakers to go in service in the United States have been developed and subjected to extensive testing. They are built of modules which can be combined for voltages of 345 kV, 500 kV, and 700 kV. The interrupting medium is SF6 gas in a completely sealed 2-pressure system, operating at constant densities. At 75°F, the higher pressure is about 240 psi; the lower is 45 psi. Contacts and blast valves of each pole unit are connected by a mechanical linkage operated by a pneumatic mechanism. The first breakers, using a mechanism designed for other breakers, have an interrupting time of 3 cycles. A special mechanism, designied for the new SF6 breakers, gives them an interrupting time of 2 cycles.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The first 500-kV 35 000-MVA breakers to go in service in the United States have been developed and subjected to extensive testing. They are built of modules which can be combined for voltages of 345 kV, 500 kV, and 700 kV. The interrupting medium is SF6 gas in a completely sealed 2-pressure system, operating at constant densities. At 75°F, the higher pressure is about 240 psi; the lower is 45 psi. Contacts and blast valves of each pole unit are connected by a mechanical linkage operated by a pneumatic mechanism. The first breakers, using a mechanism designed for other breakers, have an interrupting time of 3 cycles. A special mechanism, designied for the new SF6 breakers, gives them an interrupting time of 2 cycles.