1975IEEE Transactions on Power Apparatus and SystemsRequires access

High voltage vacuum circuit breakers

R. B. Shores, V. E. Phillips

Open publisher page 11 citations

Abstract

A new line of high voltage vacuum power circuit breakers is being developed for 121 kV and above and will use the new vacuum interrupter module presented in a companion paper3. The first ratings in production will be 242 kV with interrupting capabilities of 40,000 amperes, followed by breakers rated 50,000 amperes; both of these will have continuous current ratings of 2000 and 3000 amperes. This paper departs from normal practice by submitting the new vacuum circuit breaker design concepts prior to manufacture. A future paper on the breaker testing program and test results will be submitted to the Institute. The breakers will be dead tank design and use SF6gas only for insulation purposes. The interrupter contacts are to be mechanically driven by charged-spring type operating mechanisms. The breakers will be supplied for conventional outdoor switchyards and for high voltage gas-insulated station equipments.

About this research paper

What this paper is about

A new line of high voltage vacuum power circuit breakers is being developed for 121 kV and above and will use the new vacuum interrupter module presented in a companion paper3. The first ratings in production will be 242 kV with interrupting capabilities of 40,000 amperes, followed by breakers rated 50,000 amperes; both of these will have continuous current ratings of 2000 and 3000 amperes. This paper departs from normal practice by submitting the new vacuum circuit breaker design concepts prior to manufacture. A future paper on the breaker testing program and test results will be submitted to the Institute. The breakers will be dead tank design and use SF6gas only for insulation purposes. The interrupter contacts are to be mechanically driven by charged-spring type operating mechanisms. The breakers will be supplied for conventional outdoor switchyards and for high voltage gas-insulated station equipments.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new line of high voltage vacuum power circuit breakers is being developed for 121 kV and above and will use the new vacuum interrupter module presented in a companion paper3. The first ratings in production will be 242 kV with interrupting capabilities of 40,000 amperes, followed by breakers rated 50,000 amperes; both of these will have continuous current ratings of 2000 and 3000 amperes. This paper departs from normal practice by submitting the new vacuum circuit breaker design concepts prior to manufacture. A future paper on the breaker testing program and test results will be submitted to the Institute. The breakers will be dead tank design and use SF6gas only for insulation purposes. The interrupter contacts are to be mechanically driven by charged-spring type operating mechanisms. The breakers will be supplied for conventional outdoor switchyards and for high voltage gas-insulated station equipments.

Key concepts: Circuit breaker, Sulfur hexafluoride circuit breaker, Electrical engineering, Interrupter, High voltage, Distribution board, Ampere, Voltage

Related papers

Back to paper searchBrowse research topicsOriginal source
High voltage vacuum circuit breakers — Research Paper | ScholarLens