2014Implant DentistryRequires access

Effect of 50 to 60°C Heating on Osseointegration of Dental Implants in Dense Bone

Paolo Trisi, Marco Berardini, Antonello Falco, Michele Podaliri Vulpiani, Loredana Masciotra

Open publisher page 31 citations

Abstract

OBJECTIVES: To evaluate, in vivo, the effects of bone temperatures increased up to 60°C introduced before implant insertion on titanium implant osseointegration. MATERIALS AND METHODS: Twenty-four acid etched and sandblasted implants (Cortex Dental Implants) were inserted in the inferior edge of sheep mandibles. Osteotomic sites were randomly divided into 3 groups before inserting the implant. In test 1 group and in test 2 group, implant sites were overheated, respectively, up to 50°C for 1 minute and 60°C for 1 minute, with an electronic controlled probe of 3 mm in diameter and 10 mm in length. Osteotomic sites in control group were not overheated. Implants were inserted according to standard procedures. After 2 months healing, % bone implant contact (%BIC) and infrabony pockets' depth were measured. Unpaired t test was applied to find statistical differences between groups. RESULTS: No implant failure occurred. No statistical significant difference in %BIC was found among groups. Histological analysis showed that mean infrabony pockets were statistically deeper in 60°C group than in other groups. CONCLUSIONS: Bone temperature up to 60°C for 1 minute does not seem to significantly impair titanium dental implant osseointegration. Bone damage signs evident in the 60°C group suggest that careful drilling procedure with sufficient irrigation is necessary to avoid periimplant infrabony pockets' formation. More in vivo evaluations are needed to identify what is the value of bone temperature increase for irreversible inhibition of implant osseointegration.

About this research paper

What this paper is about

OBJECTIVES: To evaluate, in vivo, the effects of bone temperatures increased up to 60°C introduced before implant insertion on titanium implant osseointegration. MATERIALS AND METHODS: Twenty-four acid etched and sandblasted implants (Cortex Dental Implants) were inserted in the inferior edge of sheep mandibles. Osteotomic sites were randomly divided into 3 groups before inserting the implant. In test 1 group and in test 2 group, implant sites were overheated, respectively, up to 50°C for 1 minute and 60°C for 1 minute, with an electronic controlled probe of 3 mm in diameter and 10 mm in length. Osteotomic sites in control group were not overheated. Implants were inserted according to standard procedures. After 2 months healing, % bone implant contact (%BIC) and infrabony pockets' depth were measured. Unpaired t test was applied to find statistical differences between groups. RESULTS: No implant failure occurred. No statistical significant difference in %BIC was found among groups. Histological analysis showed that mean infrabony pockets were statistically deeper in 60°C group than in other groups. CONCLUSIONS: Bone temperature up to 60°C for 1 minute does not seem to significantly impair titanium dental implant osseointegration. Bone damage signs evident in the 60°C group suggest that careful drilling procedure with sufficient irrigation is necessary to avoid periimplant infrabony pockets' formation. More in vivo evaluations are needed to identify what is the value of bone temperature increase for irreversible inhibition of implant osseointegration.

Why it matters

OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVES: To evaluate, in vivo, the effects of bone temperatures increased up to 60°C introduced before implant insertion on titanium implant osseointegration. MATERIALS AND METHODS: Twenty-four acid etched and sandblasted implants (Cortex Dental Implants) were inserted in the inferior edge of sheep mandibles. Osteotomic sites were randomly divided into 3 groups before inserting the implant. In test 1 group and in test 2 group, implant sites were overheated, respectively, up to 50°C for 1 minute and 60°C for 1 minute, with an electronic controlled probe of 3 mm in diameter and 10 mm in length. Osteotomic sites in control group were not overheated. Implants were inserted according to standard procedures. After 2 months healing, % bone implant contact (%BIC) and infrabony pockets' depth were measured. Unpaired t test was applied to find statistical differences between groups. RESULTS: No implant failure occurred. No statistical significant difference in %BIC was found among groups. Histological analysis showed that mean infrabony pockets were statistically deeper in 60°C group than in other groups. CONCLUSIONS: Bone temperature up to 60°C for 1 minute does not seem to significantly impair titanium dental implant osseointegration. Bone damage signs evident in the 60°C group suggest that careful drilling procedure with sufficient irrigation is necessary to avoid periimplant infrabony pockets' formation. More in vivo evaluations are needed to identify what is the value of bone temperature increase for irreversible inhibition of implant osseointegration.

Key concepts: Osseointegration, Implant, Dentistry, Dental implant, Titanium, Significant difference, Medicine, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of 50 to 60°C Heating on Osseointegration of Dental Implants in Dense Bone — Research Paper | ScholarLens