Abstract Simple coated‐wire electrodes, prepared using an ordinary aluminum wire conductor covered with the plasticized poly(vinyl chloride) membrane, were used in potentiometric titrations of metal ions forming complexes with 1,10‐phenanthroline and its derivatives. The method precipitation of ion pairs formed by metal phenanthroline complexes and tetraphenylborate. Titractions were accompanied with titration curves yielding very sharp potential breaks, so that very reproducible results could be taken even in titrations of quite diluted solutions (down to 2.5 × 10−7 mol of the metal ion in the 25 cm3 of the sample titrated). Using the procedure described the following cations were titratable in forms of their 1.10‐phenanthroline complexes: Zn2+, Cd2+, Mn2+, Fe2+, Fe3+, Co2+, Ni2+, Cu2+, Vo2+, Ga3−, In3−, and Tl3−. Some of the metal ion solutions, prepared from the salts of analytical‐reagent‐grade purity, can be recommended for use in standardization procedures of the sodium tetraphenylborate titrant. 2.9‐Dimethyl‐1,10‐phenanthroline complexes of Zn2+, Cd2+, and Cu+ were also titrable, but the results were significantly erroneous. Metal 4,7‐diphenyl‐1,10‐phenathroline complexes were insoluble in water as well as in water/ethanol mixtures.

About this research paper

What this paper is about

Abstract Simple coated‐wire electrodes, prepared using an ordinary aluminum wire conductor covered with the plasticized poly(vinyl chloride) membrane, were used in potentiometric titrations of metal ions forming complexes with 1,10‐phenanthroline and its derivatives. The method precipitation of ion pairs formed by metal phenanthroline complexes and tetraphenylborate. Titractions were accompanied with titration curves yielding very sharp potential breaks, so that very reproducible results could be taken even in titrations of quite diluted solutions (down to 2.5 × 10−7 mol of the metal ion in the 25 cm3 of the sample titrated). Using the procedure described the following cations were titratable in forms of their 1.10‐phenanthroline complexes: Zn2+, Cd2+, Mn2+, Fe2+, Fe3+, Co2+, Ni2+, Cu2+, Vo2+, Ga3−, In3−, and Tl3−. Some of the metal ion solutions, prepared from the salts of analytical‐reagent‐grade purity, can be recommended for use in standardization procedures of the sodium tetraphenylborate titrant. 2.9‐Dimethyl‐1,10‐phenanthroline complexes of Zn2+, Cd2+, and Cu+ were also titrable, but the results were significantly erroneous. Metal 4,7‐diphenyl‐1,10‐phenathroline complexes were insoluble in water as well as in water/ethanol mixtures.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Simple coated‐wire electrodes, prepared using an ordinary aluminum wire conductor covered with the plasticized poly(vinyl chloride) membrane, were used in potentiometric titrations of metal ions forming complexes with 1,10‐phenanthroline and its derivatives. The method precipitation of ion pairs formed by metal phenanthroline complexes and tetraphenylborate. Titractions were accompanied with titration curves yielding very sharp potential breaks, so that very reproducible results could be taken even in titrations of quite diluted solutions (down to 2.5 × 10−7 mol of the metal ion in the 25 cm3 of the sample titrated). Using the procedure described the following cations were titratable in forms of their 1.10‐phenanthroline complexes: Zn2+, Cd2+, Mn2+, Fe2+, Fe3+, Co2+, Ni2+, Cu2+, Vo2+, Ga3−, In3−, and Tl3−. Some of the metal ion solutions, prepared from the salts of analytical‐reagent‐grade purity, can be recommended for use in standardization procedures of the sodium tetraphenylborate titrant. 2.9‐Dimethyl‐1,10‐phenanthroline complexes of Zn2+, Cd2+, and Cu+ were also titrable, but the results were significantly erroneous. Metal 4,7‐diphenyl‐1,10‐phenathroline complexes were insoluble in water as well as in water/ethanol mixtures.

Key concepts: Tetraphenylborate, Sodium tetraphenylborate, Potentiometric titration, Phenanthroline, Chemistry, Titration, Inorganic chemistry, Complexometric titration