2003Analytical ChemistryRequires access

Spectroscopic Features of Dual Fluorescence/Luminescence Resonance Energy-Transfer Molecular Beacons

Andrew Tsourkas, Mark A. Behlke, Yangqing Xu, Gang Bao

Open publisher page 101 citations

Abstract

Molecular beacons have the potential to become a powerful tool in gene detection and quantification in living cells. Here we report a novel dual molecular beacons approach to reduce false-positive signals in detecting target nucleic acids in homogeneous assays. A pair of molecular beacons, each containing a fluorescence quencher and a reporter fluorophore, one with a donor and a second with an acceptor fluorophore, hybridize to adjacent regions on the same target resulting in fluorescence resonance energy transfer (FRET). The detection of a FRET signal leads to a substantially increased signal-to-background ratio compared with that seen in single molecular beacon assays and enables discrimination between fluorescence due to specific probe/target hybridization and a variety of possible false-positive events. Further, when a lanthanide chelate is used as a donor in a dual-probe assay, extremely high signal-to-background ratios can be achieved owing to the long lifetime and sharp emission peaks of the donor and the time-gated detection of acceptor fluorescence emission. These new approaches allow for the ultrasensitive detection of target molecules in a way that could be readily applied to real-time imaging of gene expression in living cells.

About this research paper

What this paper is about

Molecular beacons have the potential to become a powerful tool in gene detection and quantification in living cells. Here we report a novel dual molecular beacons approach to reduce false-positive signals in detecting target nucleic acids in homogeneous assays. A pair of molecular beacons, each containing a fluorescence quencher and a reporter fluorophore, one with a donor and a second with an acceptor fluorophore, hybridize to adjacent regions on the same target resulting in fluorescence resonance energy transfer (FRET). The detection of a FRET signal leads to a substantially increased signal-to-background ratio compared with that seen in single molecular beacon assays and enables discrimination between fluorescence due to specific probe/target hybridization and a variety of possible false-positive events. Further, when a lanthanide chelate is used as a donor in a dual-probe assay, extremely high signal-to-background ratios can be achieved owing to the long lifetime and sharp emission peaks of the donor and the time-gated detection of acceptor fluorescence emission. These new approaches allow for the ultrasensitive detection of target molecules in a way that could be readily applied to real-time imaging of gene expression in living cells.

Why it matters

OpenAlex reports 101 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Molecular beacons have the potential to become a powerful tool in gene detection and quantification in living cells. Here we report a novel dual molecular beacons approach to reduce false-positive signals in detecting target nucleic acids in homogeneous assays. A pair of molecular beacons, each containing a fluorescence quencher and a reporter fluorophore, one with a donor and a second with an acceptor fluorophore, hybridize to adjacent regions on the same target resulting in fluorescence resonance energy transfer (FRET). The detection of a FRET signal leads to a substantially increased signal-to-background ratio compared with that seen in single molecular beacon assays and enables discrimination between fluorescence due to specific probe/target hybridization and a variety of possible false-positive events. Further, when a lanthanide chelate is used as a donor in a dual-probe assay, extremely high signal-to-background ratios can be achieved owing to the long lifetime and sharp emission peaks of the donor and the time-gated detection of acceptor fluorescence emission. These new approaches allow for the ultrasensitive detection of target molecules in a way that could be readily applied to real-time imaging of gene expression in living cells.

Key concepts: Molecular beacon, Fluorophore, Förster resonance energy transfer, Chemistry, Fluorescence, Fluorescence in the life sciences, Luminescence, Oligonucleotide

Related papers

Back to paper searchBrowse research topicsOriginal source
Spectroscopic Features of Dual Fluorescence/Luminescence Resonance Energy-Transfer Molecular Beacons — Research Paper | ScholarLens