Mechanical airway obstruction from laryngeal mask airway cuff
VA Ofoegbu, CN Mato
Abstract
VA Ofoegbu, CN Mato
Abstract
BACKGROUND: The laryngeal mask airway (LMA) classic has been found useful in airway management of both routine and emergency unexpected failed intubations. We report a case of mechanical airway obstruction from anterior in folding of the laryngeal mask airway classical cuff. METHOD: The anaesthetic record of a 55-year-old 70 kg female patient fora left sided total hip replacement that had a failed spinal and was augmented with the laryngeal mask airway. RESULT: Near complete airway obstruction developed after the size 4 laryngeal mask airway classic was inserted and the cuff inflated with 30 ml of air. The reduced reservoir volume and the desaturation that ensued as detected by the portable handheld pulse oximeter alerted the anesthesiologist and called for a check which was not corrected by any head and neck manoeuvre. On withdrawal of the laryngeal mask airway, the cuff was noted to have folded unto the fresh gas aperture thereby obstructing ventilation and oxygenation of the patient. CONCLUSION: Monitoring the monitors and quick reassessment of laryngeal cuff placement guaranties the evasion of anaesethetic catastrophes.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
BACKGROUND: The laryngeal mask airway (LMA) classic has been found useful in airway management of both routine and emergency unexpected failed intubations. We report a case of mechanical airway obstruction from anterior in folding of the laryngeal mask airway classical cuff. METHOD: The anaesthetic record of a 55-year-old 70 kg female patient fora left sided total hip replacement that had a failed spinal and was augmented with the laryngeal mask airway. RESULT: Near complete airway obstruction developed after the size 4 laryngeal mask airway classic was inserted and the cuff inflated with 30 ml of air. The reduced reservoir volume and the desaturation that ensued as detected by the portable handheld pulse oximeter alerted the anesthesiologist and called for a check which was not corrected by any head and neck manoeuvre. On withdrawal of the laryngeal mask airway, the cuff was noted to have folded unto the fresh gas aperture thereby obstructing ventilation and oxygenation of the patient. CONCLUSION: Monitoring the monitors and quick reassessment of laryngeal cuff placement guaranties the evasion of anaesethetic catastrophes.
Key concepts: Laryngeal mask airway, Cuff, Medicine, Airway, Airway obstruction, Mascara, Laryngeal Masks, Anesthesia