2003ElectrophoresisRequires access

Optimization of the chiral resolution of baclofen by capillary electrophoresis using β‐cyclodextrin as the chiral selector

Imran Ali, Hassan Y. Aboul‐Enein

Open publisher page 13 citations

Abstract

The chiral resolution of baclofen was achieved by capillary electrophoresis using a fused-silica capillary (60 cm x 75 microm ID). The background electrolyte (BGE) was phosphate buffer (pH 7.0, 50 mM)-acetonitrile (95:5 v/v) containing 10 mM beta-cyclodextrin. The applied voltage was 15 kV. The values of alpha and R(s) were 1.06 and 1.00, respectively. The electrophoretic conditions were optimized varying the pH and the ionic strength of the BGE, concentrations of beta-cyclodextrin and acetonitrile and the applied voltage.

About this research paper

What this paper is about

The chiral resolution of baclofen was achieved by capillary electrophoresis using a fused-silica capillary (60 cm x 75 microm ID). The background electrolyte (BGE) was phosphate buffer (pH 7.0, 50 mM)-acetonitrile (95:5 v/v) containing 10 mM beta-cyclodextrin. The applied voltage was 15 kV. The values of alpha and R(s) were 1.06 and 1.00, respectively. The electrophoretic conditions were optimized varying the pH and the ionic strength of the BGE, concentrations of beta-cyclodextrin and acetonitrile and the applied voltage.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The chiral resolution of baclofen was achieved by capillary electrophoresis using a fused-silica capillary (60 cm x 75 microm ID). The background electrolyte (BGE) was phosphate buffer (pH 7.0, 50 mM)-acetonitrile (95:5 v/v) containing 10 mM beta-cyclodextrin. The applied voltage was 15 kV. The values of alpha and R(s) were 1.06 and 1.00, respectively. The electrophoretic conditions were optimized varying the pH and the ionic strength of the BGE, concentrations of beta-cyclodextrin and acetonitrile and the applied voltage.

Key concepts: Capillary electrophoresis, Acetonitrile, Chromatography, Chemistry, Cyclodextrin, Resolution (logic), Electrophoresis, Electrolyte

Related papers

Back to paper searchBrowse research topicsOriginal source
Optimization of the chiral resolution of baclofen by capillary electrophoresis using β‐cyclodextrin as the chiral selector — Research Paper | ScholarLens