2003American Journal of RoentgenologyRequires access

Accuracy of a Collagen-Plug Biopsy Site Marking Device Deployed After Stereotactic Core Needle Breast Biopsy

Eric L. Rosen, Jay A. Baker, Mary Scott Soo

Open publisher page 39 citations

Abstract

OBJECTIVE: The goal of this study was to compare the accuracy of clip placement of a collagen-plug biopsy marking device with that of the more conventional, previously evaluated metallic tissue-marking clips. SUBJECTS AND METHODS. The placement accuracy of 31 collagen-plug marking devices was compared with the placement accuracy of 43 metallic marker clips deployed at biopsies performed between August 1, 2002, and November 20, 2002. The precision of marker placement was assessed by determining the position of the clip relative to the targeted mammographic lesion. Statistical analysis comparing the distance from the clip to the targeted lesion was performed. RESULTS: Using a two-group Wilcoxon's rank sum test, we found the clip-to-target distances for the collagen-plug central titanium marker were significantly different from the clip-to-target distances of the conventional metallic marker clips (p = 0.04). There were significantly fewer cases in which the clip-to-target distance was 1 cm or greater on at least one mammographic projection with the collagen-plug marker (5/31) than with the conventional metallic marker clip (19/43) (chi-square test, p = 0.02). CONCLUSION: The collagen-plug marking device is an effective alternative to existing marker clips, and use of this device may result in fewer cases in which the marker clip is substantially displaced (> or = 1 cm) away from the actual biopsy site.

About this research paper

What this paper is about

OBJECTIVE: The goal of this study was to compare the accuracy of clip placement of a collagen-plug biopsy marking device with that of the more conventional, previously evaluated metallic tissue-marking clips. SUBJECTS AND METHODS. The placement accuracy of 31 collagen-plug marking devices was compared with the placement accuracy of 43 metallic marker clips deployed at biopsies performed between August 1, 2002, and November 20, 2002. The precision of marker placement was assessed by determining the position of the clip relative to the targeted mammographic lesion. Statistical analysis comparing the distance from the clip to the targeted lesion was performed. RESULTS: Using a two-group Wilcoxon's rank sum test, we found the clip-to-target distances for the collagen-plug central titanium marker were significantly different from the clip-to-target distances of the conventional metallic marker clips (p = 0.04). There were significantly fewer cases in which the clip-to-target distance was 1 cm or greater on at least one mammographic projection with the collagen-plug marker (5/31) than with the conventional metallic marker clip (19/43) (chi-square test, p = 0.02). CONCLUSION: The collagen-plug marking device is an effective alternative to existing marker clips, and use of this device may result in fewer cases in which the marker clip is substantially displaced (> or = 1 cm) away from the actual biopsy site.

Why it matters

OpenAlex reports 39 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: The goal of this study was to compare the accuracy of clip placement of a collagen-plug biopsy marking device with that of the more conventional, previously evaluated metallic tissue-marking clips. SUBJECTS AND METHODS. The placement accuracy of 31 collagen-plug marking devices was compared with the placement accuracy of 43 metallic marker clips deployed at biopsies performed between August 1, 2002, and November 20, 2002. The precision of marker placement was assessed by determining the position of the clip relative to the targeted mammographic lesion. Statistical analysis comparing the distance from the clip to the targeted lesion was performed. RESULTS: Using a two-group Wilcoxon's rank sum test, we found the clip-to-target distances for the collagen-plug central titanium marker were significantly different from the clip-to-target distances of the conventional metallic marker clips (p = 0.04). There were significantly fewer cases in which the clip-to-target distance was 1 cm or greater on at least one mammographic projection with the collagen-plug marker (5/31) than with the conventional metallic marker clip (19/43) (chi-square test, p = 0.02). CONCLUSION: The collagen-plug marking device is an effective alternative to existing marker clips, and use of this device may result in fewer cases in which the marker clip is substantially displaced (> or = 1 cm) away from the actual biopsy site.

Key concepts: Medicine, Core biopsy, Biopsy, Stereotactic biopsy, Breast biopsy, Radiology, Core (optical fiber), Mammography

Related papers

Back to paper searchBrowse research topicsOriginal source
Accuracy of a Collagen-Plug Biopsy Site Marking Device Deployed After Stereotactic Core Needle Breast Biopsy — Research Paper | ScholarLens