1980Journal of Engineering for PowerRequires access

The Combined Reheat Gas Turbine/Steam Turbine Cycle: Part II—The LM 5000 Gas Generator Applied to the Combined Reheat Gas Turbine/Steam Turbine Cycle

I. G. Rice

Open publisher page 9 citations

Abstract

Part I presented an analysis of the simple and reheat gas turbine cycles and related these cycles to the combined gas turbine Rankine cycle. Part II uses the data developed in Part I and applies the second generation LM5000 to a combined cycle using a steam cycle with 1250 psig 900 FTT (8.62MPa and 482°C) steam conditions; then the reheat gas turbine is combined with a reheat steam turbine with steam conditions of 2400 psig and 1000/1000 FTT (16.55 MPa and 538/538° C). A unique arrangement of the superheater is discussed whereby part of the steam heat load is shifted to the reheat gas turbine to obtain a minimum heat recovery boiler stack temperature and a maximum cycle efficiency. This proposed power plant is projected to have a net cycle efficiency of 50 percent LHV when burning distillate fuel.

About this research paper

What this paper is about

Part I presented an analysis of the simple and reheat gas turbine cycles and related these cycles to the combined gas turbine Rankine cycle. Part II uses the data developed in Part I and applies the second generation LM5000 to a combined cycle using a steam cycle with 1250 psig 900 FTT (8.62MPa and 482°C) steam conditions; then the reheat gas turbine is combined with a reheat steam turbine with steam conditions of 2400 psig and 1000/1000 FTT (16.55 MPa and 538/538° C). A unique arrangement of the superheater is discussed whereby part of the steam heat load is shifted to the reheat gas turbine to obtain a minimum heat recovery boiler stack temperature and a maximum cycle efficiency. This proposed power plant is projected to have a net cycle efficiency of 50 percent LHV when burning distillate fuel.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Part I presented an analysis of the simple and reheat gas turbine cycles and related these cycles to the combined gas turbine Rankine cycle. Part II uses the data developed in Part I and applies the second generation LM5000 to a combined cycle using a steam cycle with 1250 psig 900 FTT (8.62MPa and 482°C) steam conditions; then the reheat gas turbine is combined with a reheat steam turbine with steam conditions of 2400 psig and 1000/1000 FTT (16.55 MPa and 538/538° C). A unique arrangement of the superheater is discussed whereby part of the steam heat load is shifted to the reheat gas turbine to obtain a minimum heat recovery boiler stack temperature and a maximum cycle efficiency. This proposed power plant is projected to have a net cycle efficiency of 50 percent LHV when burning distillate fuel.

Key concepts: Combined cycle, Heat recovery steam generator, Superheater, Steam-electric power station, Rankine cycle, Surface condenser, Boiler (water heating), Steam drum

Related papers

Back to paper searchBrowse research topicsOriginal source
The Combined Reheat Gas Turbine/Steam Turbine Cycle: Part II—The LM 5000 Gas Generator Applied to the Combined Reheat Gas Turbine/Steam Turbine Cycle — Research Paper | ScholarLens