This article provides guidance to determine the fire safety provisions for aged concrete building structures which have an age of 50 years and beyond. The ability of the aged concrete structures to resist both structural loadings and the impact of fire needs to be assessed through a combined structural and fire engineering assessment, taking into account the risk of concrete spalling in fire. It is recommended that in order to mitigate the risk of concrete spalling, additional active and/or passive fire protection may be required for the concrete having a tolerable or unacceptable risk of spalling. No additional fire safety measures would be necessary for concrete structures which have an acceptably low risk of concrete spalling occurring. © 2013 Published by Elsevier Ltd. Selection and/or peer-review under responsibility of the Asia-Oceania Association for Fire Science and Technology.

Open-access reader

About this research paper

What this paper is about

This article provides guidance to determine the fire safety provisions for aged concrete building structures which have an age of 50 years and beyond. The ability of the aged concrete structures to resist both structural loadings and the impact of fire needs to be assessed through a combined structural and fire engineering assessment, taking into account the risk of concrete spalling in fire. It is recommended that in order to mitigate the risk of concrete spalling, additional active and/or passive fire protection may be required for the concrete having a tolerable or unacceptable risk of spalling. No additional fire safety measures would be necessary for concrete structures which have an acceptably low risk of concrete spalling occurring. © 2013 Published by Elsevier Ltd. Selection and/or peer-review under responsibility of the Asia-Oceania Association for Fire Science and Technology.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This article provides guidance to determine the fire safety provisions for aged concrete building structures which have an age of 50 years and beyond. The ability of the aged concrete structures to resist both structural loadings and the impact of fire needs to be assessed through a combined structural and fire engineering assessment, taking into account the risk of concrete spalling in fire. It is recommended that in order to mitigate the risk of concrete spalling, additional active and/or passive fire protection may be required for the concrete having a tolerable or unacceptable risk of spalling. No additional fire safety measures would be necessary for concrete structures which have an acceptably low risk of concrete spalling occurring. © 2013 Published by Elsevier Ltd. Selection and/or peer-review under responsibility of the Asia-Oceania Association for Fire Science and Technology.

Key concepts: Spall, Fire safety, Forensic engineering, Engineering, Fire protection, Fire protection engineering, Fire performance, Fire resistance