Establishing a Continuous Glucose Monitoring Program
Howard Wolpert
Abstract
Howard Wolpert
Abstract
Real-time continuous glucose monitoring (RT-CGM) devices provide detailed information on glucose patterns and trends, and alarms that alert the patient to both hyper- and hypoglycemia. This technology can dramatically improve the day-to-day management of patients with diabetes and promises to be a major advance in diabetes care. The safe and effective use of RT-CGM in diabetes management rests on an understanding of several physiological as well as technological issues. This article outlines the key issues that should be addressed in the training curriculum for patients starting on RT-CGM: (1) physiologic lag between interstitial and blood glucose levels and the implications for device calibration, and interpretation and use of data in diabetes management; (2) practical considerations with the use of sensor alarms and caveats in the setting of alarm thresholds; and (3) potential risk for hypoglycemia related to excessive postprandial bolusing by RT-CGM users, and the practical implications for patient training.
OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Real-time continuous glucose monitoring (RT-CGM) devices provide detailed information on glucose patterns and trends, and alarms that alert the patient to both hyper- and hypoglycemia. This technology can dramatically improve the day-to-day management of patients with diabetes and promises to be a major advance in diabetes care. The safe and effective use of RT-CGM in diabetes management rests on an understanding of several physiological as well as technological issues. This article outlines the key issues that should be addressed in the training curriculum for patients starting on RT-CGM: (1) physiologic lag between interstitial and blood glucose levels and the implications for device calibration, and interpretation and use of data in diabetes management; (2) practical considerations with the use of sensor alarms and caveats in the setting of alarm thresholds; and (3) potential risk for hypoglycemia related to excessive postprandial bolusing by RT-CGM users, and the practical implications for patient training.
Key concepts: Continuous glucose monitoring, Hypoglycemia, Blood Glucose Self-Monitoring, Medicine, Diabetes management, Postprandial, Diabetes mellitus, Intensive care medicine