A Versatile Cobalt-60 Sample Irradiation Unit Some Design Features and Dose Measurements
G.L. Brownell, Kayla Stratton, J L Pinter
Abstract
G.L. Brownell, Kayla Stratton, J L Pinter
Abstract
The design of a 5000 curie double-well 60 Co irradiation unit is described. The 5 in. diameter × 8 in. high irradiation volume enclosed by the cylindrical source has access tubes for electrical and fluid connections to the sample during irradiation. The upper lead shield and the source are motor-driven. Operation is either by manual or fully automatic control. Dose measurements have been made with an aluminium absorbed dose calorimeter and with the ferrous-ferric system. They give 7·80±0·12×10 5 rad/hr in water (December, 1961) for the dose rate at the centre of the irradiation volume. The spatial dose distribution within the irradiation chamber has been mapped using a Plexiglas (polymethyl-methacrylate) dosemeter. Results of calibration of the radiation-induced optical absorption at 370 m μ against the ferrous-ferric system showed that the plastic dosemeter was linear with dose of 60 Co γ -rays up to 1·2×10 6 rads.
OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The design of a 5000 curie double-well 60 Co irradiation unit is described. The 5 in. diameter × 8 in. high irradiation volume enclosed by the cylindrical source has access tubes for electrical and fluid connections to the sample during irradiation. The upper lead shield and the source are motor-driven. Operation is either by manual or fully automatic control. Dose measurements have been made with an aluminium absorbed dose calorimeter and with the ferrous-ferric system. They give 7·80±0·12×10 5 rad/hr in water (December, 1961) for the dose rate at the centre of the irradiation volume. The spatial dose distribution within the irradiation chamber has been mapped using a Plexiglas (polymethyl-methacrylate) dosemeter. Results of calibration of the radiation-induced optical absorption at 370 m μ against the ferrous-ferric system showed that the plastic dosemeter was linear with dose of 60 Co γ -rays up to 1·2×10 6 rads.
Key concepts: Irradiation, Ferrous, Materials science, Cobalt-60, Calibration, Absorbed dose, Radiochemistry, Absorption (acoustics)