1971IEEE Transactions on Power Apparatus and SystemsRequires access

Switching Surge Flashover of UHV Transmission Line Insulation

A.J. Kachler, J. LaForest, L.E. Zaffanella

Open publisher page 31 citations

Abstract

The switching-surge performance of a large number of basic uhv transmission line insulation configurations has been extensively studied. The paper reports on outside phase, tower window, conductor- to-ground (with and without protrusions), conductor-to-conductor, vertical and horizontal rod-rod and rod-plane gaps. The investigated air gaps range from 10 to 66 ft (3.0 to 20.1 m) and the associated switching-surge strengths range from 1100 to 2700 kV. The paper extends earlier work1 and offers numerous design curves to the transmission line designer for uhv transmission systems up to 1500-kV system voltage.

About this research paper

What this paper is about

The switching-surge performance of a large number of basic uhv transmission line insulation configurations has been extensively studied. The paper reports on outside phase, tower window, conductor- to-ground (with and without protrusions), conductor-to-conductor, vertical and horizontal rod-rod and rod-plane gaps. The investigated air gaps range from 10 to 66 ft (3.0 to 20.1 m) and the associated switching-surge strengths range from 1100 to 2700 kV. The paper extends earlier work1 and offers numerous design curves to the transmission line designer for uhv transmission systems up to 1500-kV system voltage.

Why it matters

OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The switching-surge performance of a large number of basic uhv transmission line insulation configurations has been extensively studied. The paper reports on outside phase, tower window, conductor- to-ground (with and without protrusions), conductor-to-conductor, vertical and horizontal rod-rod and rod-plane gaps. The investigated air gaps range from 10 to 66 ft (3.0 to 20.1 m) and the associated switching-surge strengths range from 1100 to 2700 kV. The paper extends earlier work1 and offers numerous design curves to the transmission line designer for uhv transmission systems up to 1500-kV system voltage.

Key concepts: Arc flash, Conductor, Surge, Transmission line, Electrical engineering, Electric power transmission, Electrical conductor, Line (geometry)

Related papers

Back to paper searchBrowse research topicsOriginal source
Switching Surge Flashover of UHV Transmission Line Insulation — Research Paper | ScholarLens