2011American Journal of Analytical ChemistryOpen access

An Indirect Immunoassay for Detecting Antigen Based on Fluorescence Resonance Energy Transfer

Peihui Yang, Shuguang Yao, Wei Wei, Jiye Cai

Open full text 6 citations

Abstract

An indirect immunoassay for detecting antigen was developed. It was based on fluorescence resonance energy transfer (FRET) and quenching of gold nanoparticles. Bovine serum albumin (BSA) was chosen as model antigen. Fluorescein isothiocyanate (FITC) was attached to anti-BSA antibody (anti-BSA–FITC) as FRET donor, while BSA was conjugated to gold nanoparticles (GNPs–BSA) as FRET acceptor. The formation of anti-BSA–BSA immunocomplex resulted in the FRET between anti-BSA–FITC and GNPs–BSA. Thus, the fluorescence of FRET donor was quenched, and the decreasing fluorescence intensity responded linearly to the concentration of acceptor within the linear range. The concentration of BSA we obtained according to the stoichiometric ratio between BSA and GNPs. Following this approach, we were able to specifically detect BSA. The detection limit for BSA was 0.5 nM and the linear range of the assay was 2.9 - 43.5 nM. It had been successfully applied to specific detection of BSA in serum samples.

Open-access reader

About this research paper

What this paper is about

An indirect immunoassay for detecting antigen was developed. It was based on fluorescence resonance energy transfer (FRET) and quenching of gold nanoparticles. Bovine serum albumin (BSA) was chosen as model antigen. Fluorescein isothiocyanate (FITC) was attached to anti-BSA antibody (anti-BSA–FITC) as FRET donor, while BSA was conjugated to gold nanoparticles (GNPs–BSA) as FRET acceptor. The formation of anti-BSA–BSA immunocomplex resulted in the FRET between anti-BSA–FITC and GNPs–BSA. Thus, the fluorescence of FRET donor was quenched, and the decreasing fluorescence intensity responded linearly to the concentration of acceptor within the linear range. The concentration of BSA we obtained according to the stoichiometric ratio between BSA and GNPs. Following this approach, we were able to specifically detect BSA. The detection limit for BSA was 0.5 nM and the linear range of the assay was 2.9 - 43.5 nM. It had been successfully applied to specific detection of BSA in serum samples.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An indirect immunoassay for detecting antigen was developed. It was based on fluorescence resonance energy transfer (FRET) and quenching of gold nanoparticles. Bovine serum albumin (BSA) was chosen as model antigen. Fluorescein isothiocyanate (FITC) was attached to anti-BSA antibody (anti-BSA–FITC) as FRET donor, while BSA was conjugated to gold nanoparticles (GNPs–BSA) as FRET acceptor. The formation of anti-BSA–BSA immunocomplex resulted in the FRET between anti-BSA–FITC and GNPs–BSA. Thus, the fluorescence of FRET donor was quenched, and the decreasing fluorescence intensity responded linearly to the concentration of acceptor within the linear range. The concentration of BSA we obtained according to the stoichiometric ratio between BSA and GNPs. Following this approach, we were able to specifically detect BSA. The detection limit for BSA was 0.5 nM and the linear range of the assay was 2.9 - 43.5 nM. It had been successfully applied to specific detection of BSA in serum samples.

Key concepts: Förster resonance energy transfer, Bovine serum albumin, Chemistry, Detection limit, Immunoassay, Fluorescence, Colloidal gold, Fluorescein

Related papers

Back to paper searchBrowse research topicsOriginal source
An Indirect Immunoassay for Detecting Antigen Based on Fluorescence Resonance Energy Transfer — Research Paper | ScholarLens