1989Clinical ChemistryRequires access

Chromatofocusing and isoelectric focusing in immobilized pH gradients compared for characterization of human hemoglobin variants.

Renata Paleari, Cinzia Arcelloni, Rita Paroni, Isabella Fermo, Andrea Mosca

Open publisher page 5 citations

Abstract

We compared the performance of two highly resolving methods, chromatofocusing (CRF) and isoelectric focusing in immobilized pH gradients (IPGF), for the separation of human hemoglobin variants. Lysates containing 13 different hemoglobins, including variants of clinical and geographical importance, and four electrophoretically "silent" variants (Hb Brockton, Hb Cheverly, Hb Köln, and Hb Waco) were analyzed. Both techniques showed a good intrarun precision (CV = 0.87% for CRF, 0.27% for IPGF) and high and similar resolving power (0.010 pH units, with the pH gradients used in this work). The use of an ultranarrow IPGF range (pH 7.15-7.35; pH gradient = 0.019 pH/cm) allowed the resolution between Hb Brockton, Hb Köln, and Hb A. In some cases (Hb D-Los Angeles, Hb F, Hb Waco), the variants were separated from Hb A in different orders, depending on which technique was used, probably because of the different analytical principles of the two methods. As a second-level test, both procedures are informative for characterization of human hemoglobin variants.

About this research paper

What this paper is about

We compared the performance of two highly resolving methods, chromatofocusing (CRF) and isoelectric focusing in immobilized pH gradients (IPGF), for the separation of human hemoglobin variants. Lysates containing 13 different hemoglobins, including variants of clinical and geographical importance, and four electrophoretically "silent" variants (Hb Brockton, Hb Cheverly, Hb Köln, and Hb Waco) were analyzed. Both techniques showed a good intrarun precision (CV = 0.87% for CRF, 0.27% for IPGF) and high and similar resolving power (0.010 pH units, with the pH gradients used in this work). The use of an ultranarrow IPGF range (pH 7.15-7.35; pH gradient = 0.019 pH/cm) allowed the resolution between Hb Brockton, Hb Köln, and Hb A. In some cases (Hb D-Los Angeles, Hb F, Hb Waco), the variants were separated from Hb A in different orders, depending on which technique was used, probably because of the different analytical principles of the two methods. As a second-level test, both procedures are informative for characterization of human hemoglobin variants.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We compared the performance of two highly resolving methods, chromatofocusing (CRF) and isoelectric focusing in immobilized pH gradients (IPGF), for the separation of human hemoglobin variants. Lysates containing 13 different hemoglobins, including variants of clinical and geographical importance, and four electrophoretically "silent" variants (Hb Brockton, Hb Cheverly, Hb Köln, and Hb Waco) were analyzed. Both techniques showed a good intrarun precision (CV = 0.87% for CRF, 0.27% for IPGF) and high and similar resolving power (0.010 pH units, with the pH gradients used in this work). The use of an ultranarrow IPGF range (pH 7.15-7.35; pH gradient = 0.019 pH/cm) allowed the resolution between Hb Brockton, Hb Köln, and Hb A. In some cases (Hb D-Los Angeles, Hb F, Hb Waco), the variants were separated from Hb A in different orders, depending on which technique was used, probably because of the different analytical principles of the two methods. As a second-level test, both procedures are informative for characterization of human hemoglobin variants.

Key concepts: Chromatofocusing, Isoelectric focusing, Hemoglobin, Hemoglobin variants, Isoelectric point, Chromatography, Chemistry, Resolution (logic)

Related papers

Back to paper searchBrowse research topicsOriginal source
Chromatofocusing and isoelectric focusing in immobilized pH gradients compared for characterization of human hemoglobin variants. — Research Paper | ScholarLens