Assessment of pulp blood flow in primary and permanent teeth using pulse oximetry

Maria Helena Pozzobon, Ricardo de Sousa Vieira, Ana Maria Hecke Alves, Jessie Fabiola Reyes-Carmona, Cleonice da Silveira Teixeira, Beatriz Dulcinéia Mendes de Souza, Wilson Tadeu Felippe

Open publisher page 38 citations

Abstract

Pulse oximetry (PO) is a well-accepted non-invasive method for assessing vascular health, based on oxygen saturation (SaO(2) ) measurements. The objectives of this study were to design and build a custom-made PO dental sensor holder, to evaluate the effectiveness of PO in determining pulp blood flow in primary and permanent teeth, and to compare the SaO(2) levels obtained in teeth and on the little finger of patients. The PO sensor adapted to the custom-made sensor holder is termed as a device to position and hold the PO sensor. This study evaluated SaO(2) readings obtained in the pulp of 123 teeth of 84 children aged 4-13years. The teeth were divided into three groups: group I - primary teeth: 23 central incisors and 28 canines; group II - permanent teeth: 25 central incisors and 28 canines; and group III - endodontically treated teeth (control): 12 permanent central incisors and seven primary central incisors. The pulp blood flow and SaO(2) were measured and were compared with readings of the patient's finger. Data were analyzed by paired t-tests and Pearson's analysis method. The PO was able to identify all the clinically normal pulps contained in the sample, and all the endodontically treated teeth (controls) showed no response. The mean SaO(2) values were 85.27% in the teeth and 92.85% in the fingers. In conclusion, PO readings were effective in determining pulp blood flow in primary and permanent teeth. However, there was no correlation between the SaO(2) values in the fingers and in the teeth of the patients (P<0.05).

About this research paper

What this paper is about

Pulse oximetry (PO) is a well-accepted non-invasive method for assessing vascular health, based on oxygen saturation (SaO(2) ) measurements. The objectives of this study were to design and build a custom-made PO dental sensor holder, to evaluate the effectiveness of PO in determining pulp blood flow in primary and permanent teeth, and to compare the SaO(2) levels obtained in teeth and on the little finger of patients. The PO sensor adapted to the custom-made sensor holder is termed as a device to position and hold the PO sensor. This study evaluated SaO(2) readings obtained in the pulp of 123 teeth of 84 children aged 4-13years. The teeth were divided into three groups: group I - primary teeth: 23 central incisors and 28 canines; group II - permanent teeth: 25 central incisors and 28 canines; and group III - endodontically treated teeth (control): 12 permanent central incisors and seven primary central incisors. The pulp blood flow and SaO(2) were measured and were compared with readings of the patient's finger. Data were analyzed by paired t-tests and Pearson's analysis method. The PO was able to identify all the clinically normal pulps contained in the sample, and all the endodontically treated teeth (controls) showed no response. The mean SaO(2) values were 85.27% in the teeth and 92.85% in the fingers. In conclusion, PO readings were effective in determining pulp blood flow in primary and permanent teeth. However, there was no correlation between the SaO(2) values in the fingers and in the teeth of the patients (P<0.05).

Why it matters

OpenAlex reports 38 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Pulse oximetry (PO) is a well-accepted non-invasive method for assessing vascular health, based on oxygen saturation (SaO(2) ) measurements. The objectives of this study were to design and build a custom-made PO dental sensor holder, to evaluate the effectiveness of PO in determining pulp blood flow in primary and permanent teeth, and to compare the SaO(2) levels obtained in teeth and on the little finger of patients. The PO sensor adapted to the custom-made sensor holder is termed as a device to position and hold the PO sensor. This study evaluated SaO(2) readings obtained in the pulp of 123 teeth of 84 children aged 4-13years. The teeth were divided into three groups: group I - primary teeth: 23 central incisors and 28 canines; group II - permanent teeth: 25 central incisors and 28 canines; and group III - endodontically treated teeth (control): 12 permanent central incisors and seven primary central incisors. The pulp blood flow and SaO(2) were measured and were compared with readings of the patient's finger. Data were analyzed by paired t-tests and Pearson's analysis method. The PO was able to identify all the clinically normal pulps contained in the sample, and all the endodontically treated teeth (controls) showed no response. The mean SaO(2) values were 85.27% in the teeth and 92.85% in the fingers. In conclusion, PO readings were effective in determining pulp blood flow in primary and permanent teeth. However, there was no correlation between the SaO(2) values in the fingers and in the teeth of the patients (P<0.05).

Key concepts: Pulse oximetry, Pulp (tooth), Dentistry, Medicine, Blood flow, Anesthesia, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Assessment of pulp blood flow in primary and permanent teeth using pulse oximetry — Research Paper | ScholarLens