2014•Biomedical ChromatographyRequires access

The chromatographic assay of 4‐hydroxynonenal as a biomarker of diseases by means of MEPS and HPLC technique

Magdalena Ligor, Tomasz Ligor, Renata Gadzała‐Kopciuch, Bogusław Buszewski

Open publisher page 11 citations

Abstract

The aim of this study was to develop and validate a new analytical method for the determination of 4-hydroxy-2-nonenal (4-HNE) in biological samples while applying microextraction by packed sorbent as a sample preparation method and HPLC with UV-vis detection. Various microextraction by packed sorbent (MEPS) sorbents like C2 , C8 , C18 , M1 (80% C8 and 20% SCX) and silica were used to separate 4-HNE from biological samples. The highest affinity of 4-HNE was observed for sorbents like C18 . The extraction efficiency was in the range from 47.4 to 89.2% dependent on the concentration of 4-HNE. Lower efficiency of 4-HNE extraction was obtained with use of MEPS packings such as C8 and M1. The extraction efficiency was in the range from 35.2 to 66.3% for packing C8 and from 34.2 to 64.3% for packing M1, respectively. The limit of detection and lower limit of quantitation for UV-vis detection were respectively 4.5 and 9.0 nmol/mL. The proposed method can be used for the evaluation of extraction efficiency of 4-HNE in biological sample because the values of lower limit of quantitation are lower than the determined amounts of the analyte in samples. The method yields excellent performance of quantification and identification in analysis of inflammation biomarkers.

About this research paper

What this paper is about

The aim of this study was to develop and validate a new analytical method for the determination of 4-hydroxy-2-nonenal (4-HNE) in biological samples while applying microextraction by packed sorbent as a sample preparation method and HPLC with UV-vis detection. Various microextraction by packed sorbent (MEPS) sorbents like C2 , C8 , C18 , M1 (80% C8 and 20% SCX) and silica were used to separate 4-HNE from biological samples. The highest affinity of 4-HNE was observed for sorbents like C18 . The extraction efficiency was in the range from 47.4 to 89.2% dependent on the concentration of 4-HNE. Lower efficiency of 4-HNE extraction was obtained with use of MEPS packings such as C8 and M1. The extraction efficiency was in the range from 35.2 to 66.3% for packing C8 and from 34.2 to 64.3% for packing M1, respectively. The limit of detection and lower limit of quantitation for UV-vis detection were respectively 4.5 and 9.0 nmol/mL. The proposed method can be used for the evaluation of extraction efficiency of 4-HNE in biological sample because the values of lower limit of quantitation are lower than the determined amounts of the analyte in samples. The method yields excellent performance of quantification and identification in analysis of inflammation biomarkers.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The aim of this study was to develop and validate a new analytical method for the determination of 4-hydroxy-2-nonenal (4-HNE) in biological samples while applying microextraction by packed sorbent as a sample preparation method and HPLC with UV-vis detection. Various microextraction by packed sorbent (MEPS) sorbents like C2 , C8 , C18 , M1 (80% C8 and 20% SCX) and silica were used to separate 4-HNE from biological samples. The highest affinity of 4-HNE was observed for sorbents like C18 . The extraction efficiency was in the range from 47.4 to 89.2% dependent on the concentration of 4-HNE. Lower efficiency of 4-HNE extraction was obtained with use of MEPS packings such as C8 and M1. The extraction efficiency was in the range from 35.2 to 66.3% for packing C8 and from 34.2 to 64.3% for packing M1, respectively. The limit of detection and lower limit of quantitation for UV-vis detection were respectively 4.5 and 9.0 nmol/mL. The proposed method can be used for the evaluation of extraction efficiency of 4-HNE in biological sample because the values of lower limit of quantitation are lower than the determined amounts of the analyte in samples. The method yields excellent performance of quantification and identification in analysis of inflammation biomarkers.

Key concepts: Chemistry, Chromatography, Biomarker, 4-Hydroxynonenal, High-performance liquid chromatography, Biochemistry, Lipid peroxidation, Antioxidant

Related papers

Back to paper searchBrowse research topicsOriginal source
The chromatographic assay of 4‐hydroxynonenal as a biomarker of diseases by means of MEPS and HPLC technique — Research Paper | ScholarLens