2015Unpublished venueOpen access

Enhancements to the short pulse high intensity nanosecond X-radiator (SPHINX) pulsed power system

Nathan Joseph, M. E. Savage, J. Stephens, John A. Lott, Barbara Lewis, Rayburn Dean Thomas, Matthew Torres, Edward Holman

Open full text 8 citations

Abstract

The Sandia National Laboratories SPHINX accelerator is used to study the response of electronics to pulsed x-ray and electron environments. The system consists of a Marx generator and an oil-insulated pulse-forming line with self-closing oil switches. SPHINX has a peak load voltage of 2 MV and an adjustable pulse width ranging from 3 to 10 ns. The previous pulsed-power system had reliability and triggering issues with the Marx generator and subsequent undesired variations in voltage output. SPHINX was upgraded to a new Marx-generator system that has solved many of the voltage-output fluctuation and timing issues. The new Marx generator uses recently developed low-inductance 100-kV capacitors and 200-kV spark-gap switches. This paper provides an overview of SPHINX while capturing in detail the design, characterization, and comparative performance of the new Marx generator.

About this research paper

What this paper is about

The Sandia National Laboratories SPHINX accelerator is used to study the response of electronics to pulsed x-ray and electron environments. The system consists of a Marx generator and an oil-insulated pulse-forming line with self-closing oil switches. SPHINX has a peak load voltage of 2 MV and an adjustable pulse width ranging from 3 to 10 ns. The previous pulsed-power system had reliability and triggering issues with the Marx generator and subsequent undesired variations in voltage output. SPHINX was upgraded to a new Marx-generator system that has solved many of the voltage-output fluctuation and timing issues. The new Marx generator uses recently developed low-inductance 100-kV capacitors and 200-kV spark-gap switches. This paper provides an overview of SPHINX while capturing in detail the design, characterization, and comparative performance of the new Marx generator.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The Sandia National Laboratories SPHINX accelerator is used to study the response of electronics to pulsed x-ray and electron environments. The system consists of a Marx generator and an oil-insulated pulse-forming line with self-closing oil switches. SPHINX has a peak load voltage of 2 MV and an adjustable pulse width ranging from 3 to 10 ns. The previous pulsed-power system had reliability and triggering issues with the Marx generator and subsequent undesired variations in voltage output. SPHINX was upgraded to a new Marx-generator system that has solved many of the voltage-output fluctuation and timing issues. The new Marx generator uses recently developed low-inductance 100-kV capacitors and 200-kV spark-gap switches. This paper provides an overview of SPHINX while capturing in detail the design, characterization, and comparative performance of the new Marx generator.

Key concepts: Marx generator, Sphinx, Spark gap, Pulsed power, Pulse generator, Rise time, Electrical engineering, Capacitor

Related papers

Back to paper searchBrowse research topicsOriginal source
Enhancements to the short pulse high intensity nanosecond X-radiator (SPHINX) pulsed power system — Research Paper | ScholarLens