1990•PubMedOpen access

Intracranial aneurysms: evaluation by MR angiography.

Jeffrey S. Ross, Thomas J. Masaryk, Michael T. Modic, Paul M. Ruggieri, E. Mark Haacke, Warren R. Selman

Open full text 235 citations

Abstract

The purpose of this study was to compare the accuracy of a volume gradient-echo MR angiography (MRA) technique with that of intraarterial digital subtraction angiography (IA DSA) in the identification of intracranial aneurysms. The intracranial vasculature was examined in 47 patients by MRA and compared with IA DSA findings in 19 of these patients who had saccular or giant intracranial aneurysms. The remaining 28 patients, in whom no aneurysm was found, served as a control group. MRA was performed with the use of a velocity-compensated gradient-echo sequence (TR = 40-50/TE = 7-15) with a 15 degree flip angle. The sensitivity and specificity were calculated for the evaluation of the cine 3D reconstructions (cine MRA) only, cine MRA + inspection of the individual partitions, and cine MRA + individual partitions + spin-echo studies. Of 21 aneurysms, of which three were missed in two patients, the sensitivity varied from 67% for cine MRA only to 86% for the cine MRA + partitions + spin-echo studies; of the 19 patients, among whom it was assumed that the diagnosis of any one aneurysm in a patient would lead to angiography and detection of additional aneurysms, the sensitivity varied from 73% for the cine MRA only to 95% for the cine MRA + partitions + spin-echo studies. The results of this study suggest that MRA can define the circle of Willis sufficiently to allow detection of intracranial aneurysms as small as 3-4 mm. MRA holds promise as a truly noninvasive screening examination of intracranial vasculature in patients at risk for aneurysms.

About this research paper

What this paper is about

The purpose of this study was to compare the accuracy of a volume gradient-echo MR angiography (MRA) technique with that of intraarterial digital subtraction angiography (IA DSA) in the identification of intracranial aneurysms. The intracranial vasculature was examined in 47 patients by MRA and compared with IA DSA findings in 19 of these patients who had saccular or giant intracranial aneurysms. The remaining 28 patients, in whom no aneurysm was found, served as a control group. MRA was performed with the use of a velocity-compensated gradient-echo sequence (TR = 40-50/TE = 7-15) with a 15 degree flip angle. The sensitivity and specificity were calculated for the evaluation of the cine 3D reconstructions (cine MRA) only, cine MRA + inspection of the individual partitions, and cine MRA + individual partitions + spin-echo studies. Of 21 aneurysms, of which three were missed in two patients, the sensitivity varied from 67% for cine MRA only to 86% for the cine MRA + partitions + spin-echo studies; of the 19 patients, among whom it was assumed that the diagnosis of any one aneurysm in a patient would lead to angiography and detection of additional aneurysms, the sensitivity varied from 73% for the cine MRA only to 95% for the cine MRA + partitions + spin-echo studies. The results of this study suggest that MRA can define the circle of Willis sufficiently to allow detection of intracranial aneurysms as small as 3-4 mm. MRA holds promise as a truly noninvasive screening examination of intracranial vasculature in patients at risk for aneurysms.

Why it matters

OpenAlex reports 235 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The purpose of this study was to compare the accuracy of a volume gradient-echo MR angiography (MRA) technique with that of intraarterial digital subtraction angiography (IA DSA) in the identification of intracranial aneurysms. The intracranial vasculature was examined in 47 patients by MRA and compared with IA DSA findings in 19 of these patients who had saccular or giant intracranial aneurysms. The remaining 28 patients, in whom no aneurysm was found, served as a control group. MRA was performed with the use of a velocity-compensated gradient-echo sequence (TR = 40-50/TE = 7-15) with a 15 degree flip angle. The sensitivity and specificity were calculated for the evaluation of the cine 3D reconstructions (cine MRA) only, cine MRA + inspection of the individual partitions, and cine MRA + individual partitions + spin-echo studies. Of 21 aneurysms, of which three were missed in two patients, the sensitivity varied from 67% for cine MRA only to 86% for the cine MRA + partitions + spin-echo studies; of the 19 patients, among whom it was assumed that the diagnosis of any one aneurysm in a patient would lead to angiography and detection of additional aneurysms, the sensitivity varied from 73% for the cine MRA only to 95% for the cine MRA + partitions + spin-echo studies. The results of this study suggest that MRA can define the circle of Willis sufficiently to allow detection of intracranial aneurysms as small as 3-4 mm. MRA holds promise as a truly noninvasive screening examination of intracranial vasculature in patients at risk for aneurysms.

Key concepts: Medicine, Digital subtraction angiography, Aneurysm, Radiology, Magnetic resonance angiography, Angiography, Nuclear medicine, Magnetic resonance imaging

Related papers

Back to paper searchBrowse research topicsOriginal source
Intracranial aneurysms: evaluation by MR angiography. — Research Paper | ScholarLens