2012Journal of Separation ScienceRequires access

Cloud‐point extraction combined with HPLC for determination of larotaxel in rat plasma: A pharmacokinetic study of liposome formulation

Haiying Ma, Jian You, Yafei Liu

Open publisher page 13 citations

Abstract

A simple and efficient method based on cloud-point extraction combined with high-performance liquid chromatography was developed and validated for the determination of larotaxel in rat plasma. Nonionic surfactant Triton X-114 was chosen as the extraction solvent. Variable parameters affecting the cloud-point extraction efficiency, for example the nature and concentration of surfactant, NaOH concentration, incubation temperature, and time were evaluated and optimized. Chromatographic separation was accomplished on a Diamonsil C(18) column (150 mm × 4.6 mm, 5 μm) using a mobile phase consisting of acetonitrile and 0.1% phosphoric acid with pH 4.0 (60:40, v/v). The calibration curve showed good linearity over the range of 0.05-10 μg/mL. Under the optimum conditions, the method was shown to be reproducible and reliable with intraday precision below 5.7%, interday precision below 7.2%, accuracy within ±3.5%, and mean extraction recovery of 91.8-94.2%. The validated method was successfully applied to the pharmacokinetic study of larotaxel in rat plasma after a single intravenous administration of larotaxel injection and larotaxel-loaded liposome, respectively. The results indicated that the larotaxel-loaded liposome led to significant differences in pharmacokinetic profile.

About this research paper

What this paper is about

A simple and efficient method based on cloud-point extraction combined with high-performance liquid chromatography was developed and validated for the determination of larotaxel in rat plasma. Nonionic surfactant Triton X-114 was chosen as the extraction solvent. Variable parameters affecting the cloud-point extraction efficiency, for example the nature and concentration of surfactant, NaOH concentration, incubation temperature, and time were evaluated and optimized. Chromatographic separation was accomplished on a Diamonsil C(18) column (150 mm × 4.6 mm, 5 μm) using a mobile phase consisting of acetonitrile and 0.1% phosphoric acid with pH 4.0 (60:40, v/v). The calibration curve showed good linearity over the range of 0.05-10 μg/mL. Under the optimum conditions, the method was shown to be reproducible and reliable with intraday precision below 5.7%, interday precision below 7.2%, accuracy within ±3.5%, and mean extraction recovery of 91.8-94.2%. The validated method was successfully applied to the pharmacokinetic study of larotaxel in rat plasma after a single intravenous administration of larotaxel injection and larotaxel-loaded liposome, respectively. The results indicated that the larotaxel-loaded liposome led to significant differences in pharmacokinetic profile.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple and efficient method based on cloud-point extraction combined with high-performance liquid chromatography was developed and validated for the determination of larotaxel in rat plasma. Nonionic surfactant Triton X-114 was chosen as the extraction solvent. Variable parameters affecting the cloud-point extraction efficiency, for example the nature and concentration of surfactant, NaOH concentration, incubation temperature, and time were evaluated and optimized. Chromatographic separation was accomplished on a Diamonsil C(18) column (150 mm × 4.6 mm, 5 μm) using a mobile phase consisting of acetonitrile and 0.1% phosphoric acid with pH 4.0 (60:40, v/v). The calibration curve showed good linearity over the range of 0.05-10 μg/mL. Under the optimum conditions, the method was shown to be reproducible and reliable with intraday precision below 5.7%, interday precision below 7.2%, accuracy within ±3.5%, and mean extraction recovery of 91.8-94.2%. The validated method was successfully applied to the pharmacokinetic study of larotaxel in rat plasma after a single intravenous administration of larotaxel injection and larotaxel-loaded liposome, respectively. The results indicated that the larotaxel-loaded liposome led to significant differences in pharmacokinetic profile.

Key concepts: Chromatography, Cloud point, Extraction (chemistry), Phosphoric acid, Chemistry, Calibration curve, High-performance liquid chromatography, Pharmacokinetics

Related papers

Back to paper searchBrowse research topicsOriginal source
Cloud‐point extraction combined with HPLC for determination of larotaxel in rat plasma: A pharmacokinetic study of liposome formulation — Research Paper | ScholarLens