Strategies for mitigating the effects of internal arcing faults in medium-voltage metal-enclosed switchgear
Michael Wactor, Tim Olsen, Charles Ball, D.J. Lemmerman, R.J. Puckett, J.A. Zawadzki
Abstract
Michael Wactor, Tim Olsen, Charles Ball, D.J. Lemmerman, R.J. Puckett, J.A. Zawadzki
Abstract
There are numerous strategies currently employed to mitigate the effects of an internal arcing fault in medium-voltage metal-enclosed switchgear. As we learn more about the behavior of the arcing fault and how the switchgear and installation affect the severity of the fault, it is recognized that many of the techniques may be combined to improve performance. A review of the internal arcing fault and mitigation techniques is provided with discussion on how these techniques may be combined to produce positive results. When the mitigation technique has a response time that is longer than the rise time of the internal overpressure phenomenon associated with arcing faults, a need for structurally enhanced switchgear exists. A new test guide for measuring the structural enhancements is offered and strategies for coordination of arc resistant construction with mitigation techniques are discussed.
OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
There are numerous strategies currently employed to mitigate the effects of an internal arcing fault in medium-voltage metal-enclosed switchgear. As we learn more about the behavior of the arcing fault and how the switchgear and installation affect the severity of the fault, it is recognized that many of the techniques may be combined to improve performance. A review of the internal arcing fault and mitigation techniques is provided with discussion on how these techniques may be combined to produce positive results. When the mitigation technique has a response time that is longer than the rise time of the internal overpressure phenomenon associated with arcing faults, a need for structurally enhanced switchgear exists. A new test guide for measuring the structural enhancements is offered and strategies for coordination of arc resistant construction with mitigation techniques are discussed.
Key concepts: Switchgear, Electric arc, Overpressure, Fault (geology), Reliability engineering, Voltage, Circuit breaker, Arc (geometry)