2008•Seminars in DialysisRequires access

Retrospective Analysis of Catheter Recirculation in Prevalent Dialysis Patients

Shahab Moossavi, Shahab Moossavi, Tushar J. Vachharajani, Jean R. Jordan, Gregory B. Russell, Tina M. Kaufman, Shahriar Moossavi, Shahriar Moossavi

Open publisher page 17 citations

Abstract

Catheter recirculation (CR) occurs when blood returning from the venous limb of the catheter re-enters the arterial limb of the catheter without passage through the circulation. Adequacy of dialysis is influenced by the degree of access recirculation. In this study we evaluate factors influencing the degree of dialysis central venous catheter (CVC) recirculation in prevalent hemodialysis patients. This is a retrospective study of all patients undergoing hemodialysis via a catheter at the Wake Forest University Outpatient Dialysis Facilities from September 1, 2006 to May 15, 2007. CR was correlated to catheter type, catheter brand, site of placement, catheter length, time on dialysis, time on the current catheter, and was measured via ultrasound dilution technique. A total of 165 catheters were identified. Seventy-one catheters were in the right internal jugular position, 43 in the left internal jugular position, 13 in the right subclavian, one in the left subclavian, eight in the right femoral, two in the left femoral, and four in the trans-lumber position. CR was 6.3 +/- 7.5% in symmetric tip catheters (n = 14), 6.0 +/- 8.3% in split-tip catheters (n = 102), 8.4 +/- 11.7% in step-tip catheters (n = 10), and 23.0 +/- 8.2% in temporary catheters (n = 3), respectively. These results are borderline significant if temporary catheters are included (p = 0.052); however, the overall p-value is only 0.80 for tunneled dialysis catheters. There was no correlation between CR and time on dialysis (p = 0.66) or time on the current catheter (p = 0.48). The current study suggests that the CVC recirculation is independent of catheter brand, type, time on dialysis, or time on current catheter.

About this research paper

What this paper is about

Catheter recirculation (CR) occurs when blood returning from the venous limb of the catheter re-enters the arterial limb of the catheter without passage through the circulation. Adequacy of dialysis is influenced by the degree of access recirculation. In this study we evaluate factors influencing the degree of dialysis central venous catheter (CVC) recirculation in prevalent hemodialysis patients. This is a retrospective study of all patients undergoing hemodialysis via a catheter at the Wake Forest University Outpatient Dialysis Facilities from September 1, 2006 to May 15, 2007. CR was correlated to catheter type, catheter brand, site of placement, catheter length, time on dialysis, time on the current catheter, and was measured via ultrasound dilution technique. A total of 165 catheters were identified. Seventy-one catheters were in the right internal jugular position, 43 in the left internal jugular position, 13 in the right subclavian, one in the left subclavian, eight in the right femoral, two in the left femoral, and four in the trans-lumber position. CR was 6.3 +/- 7.5% in symmetric tip catheters (n = 14), 6.0 +/- 8.3% in split-tip catheters (n = 102), 8.4 +/- 11.7% in step-tip catheters (n = 10), and 23.0 +/- 8.2% in temporary catheters (n = 3), respectively. These results are borderline significant if temporary catheters are included (p = 0.052); however, the overall p-value is only 0.80 for tunneled dialysis catheters. There was no correlation between CR and time on dialysis (p = 0.66) or time on the current catheter (p = 0.48). The current study suggests that the CVC recirculation is independent of catheter brand, type, time on dialysis, or time on current catheter.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Catheter recirculation (CR) occurs when blood returning from the venous limb of the catheter re-enters the arterial limb of the catheter without passage through the circulation. Adequacy of dialysis is influenced by the degree of access recirculation. In this study we evaluate factors influencing the degree of dialysis central venous catheter (CVC) recirculation in prevalent hemodialysis patients. This is a retrospective study of all patients undergoing hemodialysis via a catheter at the Wake Forest University Outpatient Dialysis Facilities from September 1, 2006 to May 15, 2007. CR was correlated to catheter type, catheter brand, site of placement, catheter length, time on dialysis, time on the current catheter, and was measured via ultrasound dilution technique. A total of 165 catheters were identified. Seventy-one catheters were in the right internal jugular position, 43 in the left internal jugular position, 13 in the right subclavian, one in the left subclavian, eight in the right femoral, two in the left femoral, and four in the trans-lumber position. CR was 6.3 +/- 7.5% in symmetric tip catheters (n = 14), 6.0 +/- 8.3% in split-tip catheters (n = 102), 8.4 +/- 11.7% in step-tip catheters (n = 10), and 23.0 +/- 8.2% in temporary catheters (n = 3), respectively. These results are borderline significant if temporary catheters are included (p = 0.052); however, the overall p-value is only 0.80 for tunneled dialysis catheters. There was no correlation between CR and time on dialysis (p = 0.66) or time on the current catheter (p = 0.48). The current study suggests that the CVC recirculation is independent of catheter brand, type, time on dialysis, or time on current catheter.

Key concepts: Medicine, Catheter, Dialysis catheter, Hemodialysis Catheter, Dialysis, Hemodialysis, Surgery, Femoral vein

Related papers

Back to paper searchBrowse research topicsOriginal source
Retrospective Analysis of Catheter Recirculation in Prevalent Dialysis Patients — Research Paper | ScholarLens