1994PubMedOpen access

Endovascular occlusion of intracranial aneurysms with electrically detachable coils: correlation of aneurysm neck size and treatment results.

Amelia Fernández Zubillaga, Giovanni Guglielmi, Fernando Viñuela, Gary Duckwiler

Open full text 536 citations

Abstract

PURPOSE: To devise a method to measure aneurysm neck size on angiographic films, and to correlate the sizes obtained with the extent of endovascular aneurysm occlusion, performed with electrically detachable coils. METHODS: The angiograms of 79 intracranial aneurysms treated by endovascular occlusion using electrically detachable coils were retrospectively analyzed. A method using the average reported caliber of the major intracranial vessels was applied to determine the aneurysm neck sizes on the diagnostic angiograms. The cases were divided into two groups according to neck size, 4 mm being the discriminative value for small and wide necks. The posttreatment angiogram of each case was analyzed to evaluate the degree of occlusion achieved by the technique. RESULTS: Necks were successfully measured in 95% of the aneurysms. Complete aneurysm thrombosis was observed in 85% of the small-necked aneurysms and in 15% of the wide-necked aneurysms. CONCLUSIONS: Accurate angiographic measurements of neck diameter can be obtained in most aneurysms. The size of an aneurysm neck correlates well with the results of the endovascular treatment. Small-necked aneurysms can be satisfactorily occluded with this technique. In wide-necked aneurysms this technique should be reserved for lesions having a high surgical risk.

About this research paper

What this paper is about

PURPOSE: To devise a method to measure aneurysm neck size on angiographic films, and to correlate the sizes obtained with the extent of endovascular aneurysm occlusion, performed with electrically detachable coils. METHODS: The angiograms of 79 intracranial aneurysms treated by endovascular occlusion using electrically detachable coils were retrospectively analyzed. A method using the average reported caliber of the major intracranial vessels was applied to determine the aneurysm neck sizes on the diagnostic angiograms. The cases were divided into two groups according to neck size, 4 mm being the discriminative value for small and wide necks. The posttreatment angiogram of each case was analyzed to evaluate the degree of occlusion achieved by the technique. RESULTS: Necks were successfully measured in 95% of the aneurysms. Complete aneurysm thrombosis was observed in 85% of the small-necked aneurysms and in 15% of the wide-necked aneurysms. CONCLUSIONS: Accurate angiographic measurements of neck diameter can be obtained in most aneurysms. The size of an aneurysm neck correlates well with the results of the endovascular treatment. Small-necked aneurysms can be satisfactorily occluded with this technique. In wide-necked aneurysms this technique should be reserved for lesions having a high surgical risk.

Why it matters

OpenAlex reports 536 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To devise a method to measure aneurysm neck size on angiographic films, and to correlate the sizes obtained with the extent of endovascular aneurysm occlusion, performed with electrically detachable coils. METHODS: The angiograms of 79 intracranial aneurysms treated by endovascular occlusion using electrically detachable coils were retrospectively analyzed. A method using the average reported caliber of the major intracranial vessels was applied to determine the aneurysm neck sizes on the diagnostic angiograms. The cases were divided into two groups according to neck size, 4 mm being the discriminative value for small and wide necks. The posttreatment angiogram of each case was analyzed to evaluate the degree of occlusion achieved by the technique. RESULTS: Necks were successfully measured in 95% of the aneurysms. Complete aneurysm thrombosis was observed in 85% of the small-necked aneurysms and in 15% of the wide-necked aneurysms. CONCLUSIONS: Accurate angiographic measurements of neck diameter can be obtained in most aneurysms. The size of an aneurysm neck correlates well with the results of the endovascular treatment. Small-necked aneurysms can be satisfactorily occluded with this technique. In wide-necked aneurysms this technique should be reserved for lesions having a high surgical risk.

Key concepts: Medicine, Aneurysm, Occlusion, Radiology, Endovascular coiling, Endovascular treatment, Embolization, Thrombosis

Related papers

Back to paper searchBrowse research topicsOriginal source
Endovascular occlusion of intracranial aneurysms with electrically detachable coils: correlation of aneurysm neck size and treatment results. — Research Paper | ScholarLens