2013Journal of Magnetic Resonance ImagingOpen access

Optimizing isotropic three-dimensional fast spin-echo methods for imaging the knee

Charles Q. Li, Weitian Chen, Jarrett Rosenberg, Philip J. Beatty, Richard Kijowski, Brian Andrew Hargreaves, Reed F. Busse, Garry Evan Gold

Open full text 30 citations

Abstract

PURPOSE: To optimize acquisition parameters for three dimensional fast spin-echo (3D FSE) imaging of the knee. MATERIALS AND METHODS: The knees of eight healthy volunteers were imaged in a 3 Tesla MRI scanner using an eight-channel knee coil. A total of 146 intermediate weighted isotropic resolution 3D FSE (3D-FSE-Cube)images with varied acquisition parameter settings were acquired with an additional reference scan performed for subjective image quality assessment. Images were graded for overall quality, parallel imaging artifact severity and blurring. Cartilage, muscle, and fluid signal-to-noise ratios and fluid-cartilage contrast-to-noise ratios were quantified by acquiring scans without radio frequency excitation and custom-reconstructing the k-space data.Mixed effects regression modeling was used to determine statistically significant effects of different parameters on image quality. RESULTS: Changes in receiver bandwidth, repetition time and echo train length significantly affected all measurements of image quality (P < 0.05). Reducing band width improved all metrics of image quality with the exception of blurring. Reader agreement was slight to fair for subjective metrics, but overall trends in quality ratings were apparent. CONCLUSION: We used a systematic approach to optimize 3D-FSE-Cube parameters for knee imaging. Image quality was overall improved using a receiver bandwidth of 631.25 kHz, and blurring increased with lower band width and longer echo trains.

About this research paper

What this paper is about

PURPOSE: To optimize acquisition parameters for three dimensional fast spin-echo (3D FSE) imaging of the knee. MATERIALS AND METHODS: The knees of eight healthy volunteers were imaged in a 3 Tesla MRI scanner using an eight-channel knee coil. A total of 146 intermediate weighted isotropic resolution 3D FSE (3D-FSE-Cube)images with varied acquisition parameter settings were acquired with an additional reference scan performed for subjective image quality assessment. Images were graded for overall quality, parallel imaging artifact severity and blurring. Cartilage, muscle, and fluid signal-to-noise ratios and fluid-cartilage contrast-to-noise ratios were quantified by acquiring scans without radio frequency excitation and custom-reconstructing the k-space data.Mixed effects regression modeling was used to determine statistically significant effects of different parameters on image quality. RESULTS: Changes in receiver bandwidth, repetition time and echo train length significantly affected all measurements of image quality (P < 0.05). Reducing band width improved all metrics of image quality with the exception of blurring. Reader agreement was slight to fair for subjective metrics, but overall trends in quality ratings were apparent. CONCLUSION: We used a systematic approach to optimize 3D-FSE-Cube parameters for knee imaging. Image quality was overall improved using a receiver bandwidth of 631.25 kHz, and blurring increased with lower band width and longer echo trains.

Why it matters

OpenAlex reports 30 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To optimize acquisition parameters for three dimensional fast spin-echo (3D FSE) imaging of the knee. MATERIALS AND METHODS: The knees of eight healthy volunteers were imaged in a 3 Tesla MRI scanner using an eight-channel knee coil. A total of 146 intermediate weighted isotropic resolution 3D FSE (3D-FSE-Cube)images with varied acquisition parameter settings were acquired with an additional reference scan performed for subjective image quality assessment. Images were graded for overall quality, parallel imaging artifact severity and blurring. Cartilage, muscle, and fluid signal-to-noise ratios and fluid-cartilage contrast-to-noise ratios were quantified by acquiring scans without radio frequency excitation and custom-reconstructing the k-space data.Mixed effects regression modeling was used to determine statistically significant effects of different parameters on image quality. RESULTS: Changes in receiver bandwidth, repetition time and echo train length significantly affected all measurements of image quality (P < 0.05). Reducing band width improved all metrics of image quality with the exception of blurring. Reader agreement was slight to fair for subjective metrics, but overall trends in quality ratings were apparent. CONCLUSION: We used a systematic approach to optimize 3D-FSE-Cube parameters for knee imaging. Image quality was overall improved using a receiver bandwidth of 631.25 kHz, and blurring increased with lower band width and longer echo trains.

Key concepts: Image quality, Flip angle, Scanner, Fast spin echo, Bandwidth (computing), Image resolution, Computer science, Magnetic resonance imaging

Related papers

Back to paper searchBrowse research topicsOriginal source
Optimizing isotropic three-dimensional fast spin-echo methods for imaging the knee — Research Paper | ScholarLens