Determinants of intrabolus pressure during esophageal peristaltic bolus transport
J. Ren, Benson T. Massey, W. J. Dodds, Mark Kern, James G. Brasseur, Reza Shaker, S. S. Harrington, Walter J. Hogan, Ronald C. Arndorfer
Abstract
J. Ren, Benson T. Massey, W. J. Dodds, Mark Kern, James G. Brasseur, Reza Shaker, S. S. Harrington, Walter J. Hogan, Ronald C. Arndorfer
Abstract
Previous manometric studies of esophageal fluid bolus transport in humans have generally ignored the hydrodynamic distinction between intrabolus pressure and pressure within the lumen-occluded, contracting esophageal segment. In this study we obtained concurrent esophageal videofluoroscopic and intraluminal manometric recordings in supine normal volunteers using different bolus volumes and viscosities and abdominal compression. Intrabolus pressure increased with bolus volume, viscosity, and abdominal compression. Esophageal diameter increased with larger bolus volumes, and this increase was correlated with increases in intrabolus pressure. Intrabolus pressure was highest in the bolus tail. Peak intraluminal pressures > 20 mmHg above basal intrabolus pressure almost invariably were associated with effective peristalsis, whereas values of this pressure differential < 20 mmHg frequently were associated with ineffective peristalsis and retrograde bolus escape. Intrabolus pressure can serve as an important indicator of the forces resisting peristaltic transport and the occurrence of ineffective bolus transport.
OpenAlex reports 85 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Previous manometric studies of esophageal fluid bolus transport in humans have generally ignored the hydrodynamic distinction between intrabolus pressure and pressure within the lumen-occluded, contracting esophageal segment. In this study we obtained concurrent esophageal videofluoroscopic and intraluminal manometric recordings in supine normal volunteers using different bolus volumes and viscosities and abdominal compression. Intrabolus pressure increased with bolus volume, viscosity, and abdominal compression. Esophageal diameter increased with larger bolus volumes, and this increase was correlated with increases in intrabolus pressure. Intrabolus pressure was highest in the bolus tail. Peak intraluminal pressures > 20 mmHg above basal intrabolus pressure almost invariably were associated with effective peristalsis, whereas values of this pressure differential < 20 mmHg frequently were associated with ineffective peristalsis and retrograde bolus escape. Intrabolus pressure can serve as an important indicator of the forces resisting peristaltic transport and the occurrence of ineffective bolus transport.
Key concepts: Peristalsis, Bolus (digestion), Supine position, Medicine, Lumen (anatomy), Anesthesia, Esophagus, Pressure gradient