1985Journal of Clinical MicrobiologyOpen access

Comparison of a simple latex agglutination test with hemolysis-in-gel, hemagglutination inhibition, and radioimmunoassay for detection of rubella virus antibodies

Pertti Väänänen, Veli‐Mies Häivä, Pentti Koskela, Olli Meurman

Open full text 20 citations

Abstract

Rubella virus antibodies were measured in 300 sera from pregnant women visiting a maternity center by using a new, simple latex test, Rubalex. The results were compared with those obtained by using hemolysis in gel, hemagglutination inhibition, and radioimmunoassay. The sensitivity of the latex test was 100, 98.0, and 99.6% when compared with hemolysis in gel, hemagglutination inhibition, and radioimmunoassay, respectively. Its comparative specificity was 96.2, 95.7, and 90.7%, and the predictive value of a positive result was 99.2, 99.2, and 98%, respectively. When assayed with the British standard anti-rubella serum its sensitivity was 11 IU/ml. The latex test gave a positive result within 2 min, and 87% of the positive samples had already reacted after 1 min. The negative results remained as such for at least 8 min. No prozone effect was observed for sera with hemagglutination inhibition titers from 256 to 2,048. We concluded that the latex test, Rubalex, was readily applicable for measuring rubella immunity with a reaction time of 2 min in undiluted samples.

About this research paper

What this paper is about

Rubella virus antibodies were measured in 300 sera from pregnant women visiting a maternity center by using a new, simple latex test, Rubalex. The results were compared with those obtained by using hemolysis in gel, hemagglutination inhibition, and radioimmunoassay. The sensitivity of the latex test was 100, 98.0, and 99.6% when compared with hemolysis in gel, hemagglutination inhibition, and radioimmunoassay, respectively. Its comparative specificity was 96.2, 95.7, and 90.7%, and the predictive value of a positive result was 99.2, 99.2, and 98%, respectively. When assayed with the British standard anti-rubella serum its sensitivity was 11 IU/ml. The latex test gave a positive result within 2 min, and 87% of the positive samples had already reacted after 1 min. The negative results remained as such for at least 8 min. No prozone effect was observed for sera with hemagglutination inhibition titers from 256 to 2,048. We concluded that the latex test, Rubalex, was readily applicable for measuring rubella immunity with a reaction time of 2 min in undiluted samples.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Rubella virus antibodies were measured in 300 sera from pregnant women visiting a maternity center by using a new, simple latex test, Rubalex. The results were compared with those obtained by using hemolysis in gel, hemagglutination inhibition, and radioimmunoassay. The sensitivity of the latex test was 100, 98.0, and 99.6% when compared with hemolysis in gel, hemagglutination inhibition, and radioimmunoassay, respectively. Its comparative specificity was 96.2, 95.7, and 90.7%, and the predictive value of a positive result was 99.2, 99.2, and 98%, respectively. When assayed with the British standard anti-rubella serum its sensitivity was 11 IU/ml. The latex test gave a positive result within 2 min, and 87% of the positive samples had already reacted after 1 min. The negative results remained as such for at least 8 min. No prozone effect was observed for sera with hemagglutination inhibition titers from 256 to 2,048. We concluded that the latex test, Rubalex, was readily applicable for measuring rubella immunity with a reaction time of 2 min in undiluted samples.

Key concepts: Rubella, Hemagglutination assay, Radioimmunoassay, Rubella virus, Latex fixation test, Hemolysis, Hemagglutination, Titer

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of a simple latex agglutination test with hemolysis-in-gel, hemagglutination inhibition, and radioimmunoassay for detection of rubella virus antibodies — Research Paper | ScholarLens