2003American MineralogistRequires access

Melting of garnet peridotite: Effects of capsules and thermocouples, and implications for the high-pressure mantle solidus

Charles E. Lesher, J. Pickering-Witter, G. Baxter, Michael J. Walter

Open publisher page 27 citations

Abstract

Experimental solidus determinations for nominally anhydrous fertile peridotites at 4-6 GPa differ by as much as 150°C. These differences have recently been ascribed to experimental methods, specifically, the use of graphite capsules leading to elevated CO 2 contents during the runs. We examine this claim by directly comparing phase relations of fertile peridotite KR4003 encapsulated in rhenium and graphite sealed in Pt, using an extensively calibrated double capsule and thermocouple assembly. Experiments are conducted at 5 GPa and 1750 to 1575 °C using the MA6/8 multianvil apparatus. We found that the phase assemblages recovered from both capsules of a given experiment are largely indistinguishable down to solidus conditions. The solidus is estimated to be 1600 ± 15°C, in good agreement with previous experiments on KR4003, but substantially below most other determinations for garnet peridotite solidi at 5 GPa. We find Opx to be stable at the solidus of KR4003 at 5 GPa, in contrast to earlier findings and relate its stability to Fe 3+ content. Our work further shows that a loss of calibration of the W-Re thermocouple circuit connected through the Re capsule at high temperatures is of the same order as the temperature discrepancy reported previously for fertile peridotite solidi. Revisions to the anhydrous peridotite solidus at high pressures invite reconsideration of potential temperatures of mantle plumes, which could be as much as 150°C lower than commonly assumed

About this research paper

What this paper is about

Experimental solidus determinations for nominally anhydrous fertile peridotites at 4-6 GPa differ by as much as 150°C. These differences have recently been ascribed to experimental methods, specifically, the use of graphite capsules leading to elevated CO 2 contents during the runs. We examine this claim by directly comparing phase relations of fertile peridotite KR4003 encapsulated in rhenium and graphite sealed in Pt, using an extensively calibrated double capsule and thermocouple assembly. Experiments are conducted at 5 GPa and 1750 to 1575 °C using the MA6/8 multianvil apparatus. We found that the phase assemblages recovered from both capsules of a given experiment are largely indistinguishable down to solidus conditions. The solidus is estimated to be 1600 ± 15°C, in good agreement with previous experiments on KR4003, but substantially below most other determinations for garnet peridotite solidi at 5 GPa. We find Opx to be stable at the solidus of KR4003 at 5 GPa, in contrast to earlier findings and relate its stability to Fe 3+ content. Our work further shows that a loss of calibration of the W-Re thermocouple circuit connected through the Re capsule at high temperatures is of the same order as the temperature discrepancy reported previously for fertile peridotite solidi. Revisions to the anhydrous peridotite solidus at high pressures invite reconsideration of potential temperatures of mantle plumes, which could be as much as 150°C lower than commonly assumed

Why it matters

OpenAlex reports 27 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Experimental solidus determinations for nominally anhydrous fertile peridotites at 4-6 GPa differ by as much as 150°C. These differences have recently been ascribed to experimental methods, specifically, the use of graphite capsules leading to elevated CO 2 contents during the runs. We examine this claim by directly comparing phase relations of fertile peridotite KR4003 encapsulated in rhenium and graphite sealed in Pt, using an extensively calibrated double capsule and thermocouple assembly. Experiments are conducted at 5 GPa and 1750 to 1575 °C using the MA6/8 multianvil apparatus. We found that the phase assemblages recovered from both capsules of a given experiment are largely indistinguishable down to solidus conditions. The solidus is estimated to be 1600 ± 15°C, in good agreement with previous experiments on KR4003, but substantially below most other determinations for garnet peridotite solidi at 5 GPa. We find Opx to be stable at the solidus of KR4003 at 5 GPa, in contrast to earlier findings and relate its stability to Fe 3+ content. Our work further shows that a loss of calibration of the W-Re thermocouple circuit connected through the Re capsule at high temperatures is of the same order as the temperature discrepancy reported previously for fertile peridotite solidi. Revisions to the anhydrous peridotite solidus at high pressures invite reconsideration of potential temperatures of mantle plumes, which could be as much as 150°C lower than commonly assumed

Key concepts: Solidus, Peridotite, Mantle (geology), Anhydrous, Geology, Mineralogy, Thermocouple, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Melting of garnet peridotite: Effects of capsules and thermocouples, and implications for the high-pressure mantle solidus — Research Paper | ScholarLens