This paper describes a field experience on geogrid-reinforced soil walls rising up to 29.5m in height. Since experiences of design and construction on very high-raised geogrid reinforced soil wall were limited, thorough design and construction management was performed for safe construction of the wall. Regarding design of the wall, both internal and external stabilities were examined based on the design guideline specified by FHWA and overall slope stability analyses were performed by using Bishop simplified method. Moreover, a series of instrumentations were performed. The results of instrumentation for two tiered reinforced soil wall showed that not only the deformations of both the wall face and the reinforcement but also the horizontal earth pressures acting on the wall facing were very small. These results indicate that the reinforced soil wall technology can be applied successfully for high-raised tiered wall more than 20m heights and FHWA design guideline is very conservative for that large wall.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This paper describes a field experience on geogrid-reinforced soil walls rising up to 29.5m in height. Since experiences of design and construction on very high-raised geogrid reinforced soil wall were limited, thorough design and construction management was performed for safe construction of the wall. Regarding design of the wall, both internal and external stabilities were examined based on the design guideline specified by FHWA and overall slope stability analyses were performed by using Bishop simplified method. Moreover, a series of instrumentations were performed. The results of instrumentation for two tiered reinforced soil wall showed that not only the deformations of both the wall face and the reinforcement but also the horizontal earth pressures acting on the wall facing were very small. These results indicate that the reinforced soil wall technology can be applied successfully for high-raised tiered wall more than 20m heights and FHWA design guideline is very conservative for that large wall.
Key concepts: Mechanically stabilized earth, Retaining wall, Geogrid, Geotechnical engineering, Structural engineering, Instrumentation (computer programming), Lateral earth pressure, Engineering