1978PubMedRequires access

Simultaneous liquid-chromatographic determination of 12 common sedatives and hypnotics in serum.

P M Kabra, H Y Koo, L J Marton

Open publisher page 47 citations

Abstract

We present a method for simultaneously determining 12 hypnotics and sedatives (primidone, methyprylon, phenobarbital, butabarbital, butalbital, ethchlorvynol, pentobarbital, amobarbital, phenytoin, glutethimide, secobarbital and methaqualone) in 200 microliter of serum. Serum proteins are precipitated with an acetonitrile solution containing 5-(4-methylphenyl)-5-phenylhydantoin, the internal standard. The drugs are eluted from a reversed-phase column with a mobile phase consisting of an acetonitrile/phosphate buffer, at a flow rate of 3.0 ml/min. The eluted drugs are detected by their absorption at 195 nm; their quantities are estimated from their peak heights. Each analysis requires no longer than 30 min at the optimum column temperature of 50 degrees C. The lower limit of detection for all of these drugs is less than 10 ng/sample for drug standard. A sensitivity of 1.0 mg/liter of serum is attained routinely for each of the drugs. Analytical recoveries for the 12 drugs varied from 94 to 112%, with good day-to-day precision (CV between 3.8 and 10.4%). Of more than 35 drugs tested for possible interference, only ethotoin interferes with the analysis of phenobarbital.

About this research paper

What this paper is about

We present a method for simultaneously determining 12 hypnotics and sedatives (primidone, methyprylon, phenobarbital, butabarbital, butalbital, ethchlorvynol, pentobarbital, amobarbital, phenytoin, glutethimide, secobarbital and methaqualone) in 200 microliter of serum. Serum proteins are precipitated with an acetonitrile solution containing 5-(4-methylphenyl)-5-phenylhydantoin, the internal standard. The drugs are eluted from a reversed-phase column with a mobile phase consisting of an acetonitrile/phosphate buffer, at a flow rate of 3.0 ml/min. The eluted drugs are detected by their absorption at 195 nm; their quantities are estimated from their peak heights. Each analysis requires no longer than 30 min at the optimum column temperature of 50 degrees C. The lower limit of detection for all of these drugs is less than 10 ng/sample for drug standard. A sensitivity of 1.0 mg/liter of serum is attained routinely for each of the drugs. Analytical recoveries for the 12 drugs varied from 94 to 112%, with good day-to-day precision (CV between 3.8 and 10.4%). Of more than 35 drugs tested for possible interference, only ethotoin interferes with the analysis of phenobarbital.

Why it matters

OpenAlex reports 47 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We present a method for simultaneously determining 12 hypnotics and sedatives (primidone, methyprylon, phenobarbital, butabarbital, butalbital, ethchlorvynol, pentobarbital, amobarbital, phenytoin, glutethimide, secobarbital and methaqualone) in 200 microliter of serum. Serum proteins are precipitated with an acetonitrile solution containing 5-(4-methylphenyl)-5-phenylhydantoin, the internal standard. The drugs are eluted from a reversed-phase column with a mobile phase consisting of an acetonitrile/phosphate buffer, at a flow rate of 3.0 ml/min. The eluted drugs are detected by their absorption at 195 nm; their quantities are estimated from their peak heights. Each analysis requires no longer than 30 min at the optimum column temperature of 50 degrees C. The lower limit of detection for all of these drugs is less than 10 ng/sample for drug standard. A sensitivity of 1.0 mg/liter of serum is attained routinely for each of the drugs. Analytical recoveries for the 12 drugs varied from 94 to 112%, with good day-to-day precision (CV between 3.8 and 10.4%). Of more than 35 drugs tested for possible interference, only ethotoin interferes with the analysis of phenobarbital.

Key concepts: Secobarbital, Methaqualone, Glutethimide, Primidone, Chromatography, Barbital, Chemistry, Amobarbital

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous liquid-chromatographic determination of 12 common sedatives and hypnotics in serum. — Research Paper | ScholarLens