2009PubMedRequires access

Application of intraoperative round window electrocochleography for screening the patients with auditory neuropathy.

Line Wang, Zhen Wang, Daoxing Zhang, Keli Cao

Open publisher page 3 citations

Abstract

BACKGROUND: Most patients with auditory neuropathy (AN) could receive good even the best effects after cochlear implantation. How to diagnose AN objectively and accurately is very important. In this study, we screened the patients with AN according to the presence or absence of compound action potential (CAP) of intraoperative round window electrocochleography (RW ECochG). METHODS: Intraoperative RW ECochG was performed on 32 patients with profound sensorineural deafness, who had normal cochlea during cochlear implantation surgery under general anesthesia in the standard operating room. The cochlear microphonic (CM) and CAP of RW ECochG was observed and recorded. RESULTS: The presence of CM but the absence of CAP of RW ECochG occurred in 12 among the 32 patients. They were suspected to suffer from AN. The rest patients who had CM and CAP of RW ECochG were thought not to suffer from AN. CONCLUSION: Application of intraoperative RW ECochG during the cochlear implantation surgery may objectively and accurately screen the patients with AN, and can give a meaningful clue for implanted device working.

About this research paper

What this paper is about

BACKGROUND: Most patients with auditory neuropathy (AN) could receive good even the best effects after cochlear implantation. How to diagnose AN objectively and accurately is very important. In this study, we screened the patients with AN according to the presence or absence of compound action potential (CAP) of intraoperative round window electrocochleography (RW ECochG). METHODS: Intraoperative RW ECochG was performed on 32 patients with profound sensorineural deafness, who had normal cochlea during cochlear implantation surgery under general anesthesia in the standard operating room. The cochlear microphonic (CM) and CAP of RW ECochG was observed and recorded. RESULTS: The presence of CM but the absence of CAP of RW ECochG occurred in 12 among the 32 patients. They were suspected to suffer from AN. The rest patients who had CM and CAP of RW ECochG were thought not to suffer from AN. CONCLUSION: Application of intraoperative RW ECochG during the cochlear implantation surgery may objectively and accurately screen the patients with AN, and can give a meaningful clue for implanted device working.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Most patients with auditory neuropathy (AN) could receive good even the best effects after cochlear implantation. How to diagnose AN objectively and accurately is very important. In this study, we screened the patients with AN according to the presence or absence of compound action potential (CAP) of intraoperative round window electrocochleography (RW ECochG). METHODS: Intraoperative RW ECochG was performed on 32 patients with profound sensorineural deafness, who had normal cochlea during cochlear implantation surgery under general anesthesia in the standard operating room. The cochlear microphonic (CM) and CAP of RW ECochG was observed and recorded. RESULTS: The presence of CM but the absence of CAP of RW ECochG occurred in 12 among the 32 patients. They were suspected to suffer from AN. The rest patients who had CM and CAP of RW ECochG were thought not to suffer from AN. CONCLUSION: Application of intraoperative RW ECochG during the cochlear implantation surgery may objectively and accurately screen the patients with AN, and can give a meaningful clue for implanted device working.

Key concepts: Electrocochleography, Medicine, Round window, Auditory neuropathy, Cochlear implantation, Audiology, Cochlea, Hearing loss

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of intraoperative round window electrocochleography for screening the patients with auditory neuropathy. — Research Paper | ScholarLens