2012Acta Anaesthesiologica ScandinavicaRequires access

Lung elastance and transpulmonary pressure can be determined without using oesophageal pressure measurements

Ola Stenqvist, Christina Grivans, B. Andersson, Susanne Lundin

Open publisher page 38 citations

Abstract

INTRODUCTION: The aim of the present study was to demonstrate that lung elastance and transpulmonary pressure can be determined without using oesophageal pressure measurements. METHODS: Studies were performed on 13 anesthetized and sacrificed ex vivo pigs. Tracheal and oesophageal pressures were measured and changes in end-expiratory lung volume (ΔEELV) determined by spirometry as the cumulative inspiratory-expiratory tidal volume difference. Studies were performed with different end-expiratory pressure steps [change in end-expiratory airway pressure (ΔPEEP)], body positions and with abdominal load. RESULTS: A PEEP increase results in a multi-breath build-up of end-expiratory lung volume. End-expiratory oesophageal pressure did not increase further after the first expiration, constituting half of the change in ΔEELV following a PEEP increase, even though end-expiratory volume continued to increase. This resulted in a successive left shift of the chest wall pressure-volume curve. Even at a PEEP of 12 cmH(2) O did the end-expiratory oesophageal (pleural) pressure remain negative. CONCLUSIONS: A PEEP increase resulted in a less than expected increase in end-expiratory oesophageal pressure, indicating that the chest wall and abdomen gradually can accommodate changes in lung volume. The rib cage end-expiratory spring-out force stretches the diaphragm and prevents the lung from being compressed by abdominal pressure. The increase in transpulmonary pressure following a PEEP increase was closely related to the increase in PEEP, indicating that lung compliance can be calculated from the ratio of the change in end-expiratory lung volume and the change in PEEP, ΔEELV/ΔPEEP.

About this research paper

What this paper is about

INTRODUCTION: The aim of the present study was to demonstrate that lung elastance and transpulmonary pressure can be determined without using oesophageal pressure measurements. METHODS: Studies were performed on 13 anesthetized and sacrificed ex vivo pigs. Tracheal and oesophageal pressures were measured and changes in end-expiratory lung volume (ΔEELV) determined by spirometry as the cumulative inspiratory-expiratory tidal volume difference. Studies were performed with different end-expiratory pressure steps [change in end-expiratory airway pressure (ΔPEEP)], body positions and with abdominal load. RESULTS: A PEEP increase results in a multi-breath build-up of end-expiratory lung volume. End-expiratory oesophageal pressure did not increase further after the first expiration, constituting half of the change in ΔEELV following a PEEP increase, even though end-expiratory volume continued to increase. This resulted in a successive left shift of the chest wall pressure-volume curve. Even at a PEEP of 12 cmH(2) O did the end-expiratory oesophageal (pleural) pressure remain negative. CONCLUSIONS: A PEEP increase resulted in a less than expected increase in end-expiratory oesophageal pressure, indicating that the chest wall and abdomen gradually can accommodate changes in lung volume. The rib cage end-expiratory spring-out force stretches the diaphragm and prevents the lung from being compressed by abdominal pressure. The increase in transpulmonary pressure following a PEEP increase was closely related to the increase in PEEP, indicating that lung compliance can be calculated from the ratio of the change in end-expiratory lung volume and the change in PEEP, ΔEELV/ΔPEEP.

Why it matters

OpenAlex reports 38 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

INTRODUCTION: The aim of the present study was to demonstrate that lung elastance and transpulmonary pressure can be determined without using oesophageal pressure measurements. METHODS: Studies were performed on 13 anesthetized and sacrificed ex vivo pigs. Tracheal and oesophageal pressures were measured and changes in end-expiratory lung volume (ΔEELV) determined by spirometry as the cumulative inspiratory-expiratory tidal volume difference. Studies were performed with different end-expiratory pressure steps [change in end-expiratory airway pressure (ΔPEEP)], body positions and with abdominal load. RESULTS: A PEEP increase results in a multi-breath build-up of end-expiratory lung volume. End-expiratory oesophageal pressure did not increase further after the first expiration, constituting half of the change in ΔEELV following a PEEP increase, even though end-expiratory volume continued to increase. This resulted in a successive left shift of the chest wall pressure-volume curve. Even at a PEEP of 12 cmH(2) O did the end-expiratory oesophageal (pleural) pressure remain negative. CONCLUSIONS: A PEEP increase resulted in a less than expected increase in end-expiratory oesophageal pressure, indicating that the chest wall and abdomen gradually can accommodate changes in lung volume. The rib cage end-expiratory spring-out force stretches the diaphragm and prevents the lung from being compressed by abdominal pressure. The increase in transpulmonary pressure following a PEEP increase was closely related to the increase in PEEP, indicating that lung compliance can be calculated from the ratio of the change in end-expiratory lung volume and the change in PEEP, ΔEELV/ΔPEEP.

Key concepts: Transpulmonary pressure, Medicine, Positive end-expiratory pressure, Lung volumes, Anesthesia, Pulmonary compliance, Lung, Spirometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Lung elastance and transpulmonary pressure can be determined without using oesophageal pressure measurements — Research Paper | ScholarLens