Comparison of Indirect CsI/a:Si and Direct a: Se Digital Radiography. An assessment of contrast and detail visualization

Frank Fischbach, T. Freund, Maciej Pech, Michael Werk, C. Bassir, B. Stoever, R. Félix, Jens Ricke

Open publisher page 13 citations

Abstract

PURPOSE: To assess and quantify the image quality at two dose levels for an amorphous Silicon (a:Si) Cesium Iodide (CsI) flat panel system compared with a direct amorphous Selenium (a:Se) digital radiography system. MATERIAL AND METHODS: A contrast detectability test was performed employing the CDRAD-phantom at mAs-values leading to approximately equal phantom entrance doses of 41.4, 57.9, 75.1 and 120.8 micro Gy for the a:Se and 39.9, 58.4, 75.6 and 117.9 micro Gy for the CsI system. Images were presented to 4 independent observers. For quantitative comparison, the image quality figure (IQF) was calculated. Statistical analysis was performed using Pearson's correlation and the Wilcoxon test. A ROC-analysis was performed employing the TRG-phantom in a high- and a low-dose setting leading to entrance doses of 126.2 and 35 micro Gy for the direct, and 125.9 and 34.4 micro Gy for the indirect system. Statistical significance was evaluated using the Wilcoxon test. RESULTS: The flat panel a:Si digital system provided superior results compared with the a:Se drum digital system with respect to low-dose settings for CDRAD-phantom and ROC-analysis, ensuring a better image quality with respect to contrast and detail detectability. Higher-dose settings provided similar results for both systems. CONCLUSION: Image quality of a:Si flat panel digital radiography proved to be superior to a:Se drum digital radiography using low-dose settings. If the primary target is dose reduction indirect flat panel technology should be used.

About this research paper

What this paper is about

PURPOSE: To assess and quantify the image quality at two dose levels for an amorphous Silicon (a:Si) Cesium Iodide (CsI) flat panel system compared with a direct amorphous Selenium (a:Se) digital radiography system. MATERIAL AND METHODS: A contrast detectability test was performed employing the CDRAD-phantom at mAs-values leading to approximately equal phantom entrance doses of 41.4, 57.9, 75.1 and 120.8 micro Gy for the a:Se and 39.9, 58.4, 75.6 and 117.9 micro Gy for the CsI system. Images were presented to 4 independent observers. For quantitative comparison, the image quality figure (IQF) was calculated. Statistical analysis was performed using Pearson's correlation and the Wilcoxon test. A ROC-analysis was performed employing the TRG-phantom in a high- and a low-dose setting leading to entrance doses of 126.2 and 35 micro Gy for the direct, and 125.9 and 34.4 micro Gy for the indirect system. Statistical significance was evaluated using the Wilcoxon test. RESULTS: The flat panel a:Si digital system provided superior results compared with the a:Se drum digital system with respect to low-dose settings for CDRAD-phantom and ROC-analysis, ensuring a better image quality with respect to contrast and detail detectability. Higher-dose settings provided similar results for both systems. CONCLUSION: Image quality of a:Si flat panel digital radiography proved to be superior to a:Se drum digital radiography using low-dose settings. If the primary target is dose reduction indirect flat panel technology should be used.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To assess and quantify the image quality at two dose levels for an amorphous Silicon (a:Si) Cesium Iodide (CsI) flat panel system compared with a direct amorphous Selenium (a:Se) digital radiography system. MATERIAL AND METHODS: A contrast detectability test was performed employing the CDRAD-phantom at mAs-values leading to approximately equal phantom entrance doses of 41.4, 57.9, 75.1 and 120.8 micro Gy for the a:Se and 39.9, 58.4, 75.6 and 117.9 micro Gy for the CsI system. Images were presented to 4 independent observers. For quantitative comparison, the image quality figure (IQF) was calculated. Statistical analysis was performed using Pearson's correlation and the Wilcoxon test. A ROC-analysis was performed employing the TRG-phantom in a high- and a low-dose setting leading to entrance doses of 126.2 and 35 micro Gy for the direct, and 125.9 and 34.4 micro Gy for the indirect system. Statistical significance was evaluated using the Wilcoxon test. RESULTS: The flat panel a:Si digital system provided superior results compared with the a:Se drum digital system with respect to low-dose settings for CDRAD-phantom and ROC-analysis, ensuring a better image quality with respect to contrast and detail detectability. Higher-dose settings provided similar results for both systems. CONCLUSION: Image quality of a:Si flat panel digital radiography proved to be superior to a:Se drum digital radiography using low-dose settings. If the primary target is dose reduction indirect flat panel technology should be used.

Key concepts: Medicine, Radiography, Contrast (vision), Visualization, Digital radiography, Nuclear medicine, Medical physics, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of Indirect CsI/a:Si and Direct a: Se Digital Radiography. An assessment of contrast and detail visualization — Research Paper | ScholarLens