Analysis of ventilation profile during six minutes walking test: Preliminary study
Giancarlo Piaggi, Manuela Piran, Verónica Rossi, Serena Cirio, Piero Ceriana
Abstract
Giancarlo Piaggi, Manuela Piran, Verónica Rossi, Serena Cirio, Piero Ceriana
Abstract
Background: The evolution of the Respiratory Therapy has led us to cure the patients with comorbidities and/or chronically ill. Moreover, it has induced us to suspect that the six-minutes walking test (6-MWT) might be maximal for subgroup of patients. Aim: Firstly, verify the percentage of patients of whom the 6-MWT has a maximal trend (6-MWT max) by analyzing their ventilation profile during the test. Secondly, identify the threshold characteristics and predictor parameters of patient’ 6-MWT max. Methods: 97 COPD patients performed forced vital capacity (FVC), forced espiratory volume in 1 sec (FEV1), FEV1/FVC%, maximal voluntary ventilation, inspiratory capacity (CI), minute ventilation (VE) with portable spirometer Spiropalm®, before and immediately after 6-MWT. In the 6-MWT max we calculated the best thresholds using the resampling procedure called “bootstrapping”, in order to discriminate whether the test was a maximal performance or not. The discrimination capability of each threshold was evaluated in terms of accuracy of classification. Results: About 70% of patients recruited achieved a 6-MWT max for symptoms, HR or VE max. About 57% of patients had a maximal performance exclusively from the ventilatory index. The most predictive parameters for a maximal test were: FEV1/FVC < 46% (p < 1x10 -5), FEV1% < 44% (p < 1x10 -5) e MVV < 46.5 (p < 1x10 -5). Conclusion: Preliminary data suggest that FEV1/FVC%, FEV1% and MVV are predictor factors for a maximal performance. The 6MWT may underestimate the real potential of the patient. Instead, it would be more useful to assess, before starting the training, weather the 6-MWT was a maximal test or not.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Background: The evolution of the Respiratory Therapy has led us to cure the patients with comorbidities and/or chronically ill. Moreover, it has induced us to suspect that the six-minutes walking test (6-MWT) might be maximal for subgroup of patients. Aim: Firstly, verify the percentage of patients of whom the 6-MWT has a maximal trend (6-MWT max) by analyzing their ventilation profile during the test. Secondly, identify the threshold characteristics and predictor parameters of patient’ 6-MWT max. Methods: 97 COPD patients performed forced vital capacity (FVC), forced espiratory volume in 1 sec (FEV1), FEV1/FVC%, maximal voluntary ventilation, inspiratory capacity (CI), minute ventilation (VE) with portable spirometer Spiropalm®, before and immediately after 6-MWT. In the 6-MWT max we calculated the best thresholds using the resampling procedure called “bootstrapping”, in order to discriminate whether the test was a maximal performance or not. The discrimination capability of each threshold was evaluated in terms of accuracy of classification. Results: About 70% of patients recruited achieved a 6-MWT max for symptoms, HR or VE max. About 57% of patients had a maximal performance exclusively from the ventilatory index. The most predictive parameters for a maximal test were: FEV1/FVC < 46% (p < 1x10 -5), FEV1% < 44% (p < 1x10 -5) e MVV < 46.5 (p < 1x10 -5). Conclusion: Preliminary data suggest that FEV1/FVC%, FEV1% and MVV are predictor factors for a maximal performance. The 6MWT may underestimate the real potential of the patient. Instead, it would be more useful to assess, before starting the training, weather the 6-MWT was a maximal test or not.
Key concepts: Medicine, Spirometer, COPD, Vital capacity, Physical therapy, Respiratory minute volume, Internal medicine, Ventilation (architecture)