1993PubMedRequires access

Safe intraabdominal pressure of carbon dioxide pneumoperitoneum during laparoscopic surgery.

Y Ishizaki, Yasutsugu Bandai, Kazuyuki Shimomura, Hideki Abe, Y Ohtomo, Y Idezuki

Open publisher page 71 citations

Abstract

BACKGROUND: The deliberate induction of carbon dioxide pneumoperitoneum during laparoscopic surgery could be a possible source of cardiovascular collapse. The effects of elevated intraabdominal pressure (IAP) on systemic hemodynamics and splanchnic blood flow created by insufflation of carbon dioxide were examined in anesthetized dogs. METHODS: Stepwise increases in IAP of 8 (n = 7), 12 (n = 7), and 16 (n = 7) mm Hg were applied to determine the threshold pressure that had minimum influence on these hemodynamics. Hemodynamic parameters were measured at baseline and 1, 2, and 3 hours after the start of insufflation. RESULTS: At an IAP of 16 mm Hg, cardiac output was decreased significantly by 1 hour after the start of insufflation and became progressively lower during the procedure. Systemic vascular resistance was elevated significantly in parallel with the change in cardiac output. Although hepatic arterial blood flow was not decreased significantly, portal venous and superior mesenteric arterial blood flows were diminished significantly at 16 mm Hg, resulting in a decrease in total hepatic blood flow. No significant changes were observed in these parameters at 8 or 12 mm Hg. CONCLUSIONS: Based on these results, an IAP from 8 to 12 mm Hg is recommended for laparoscopic surgery, to avoid complications caused by hemodynamic derangements.

About this research paper

What this paper is about

BACKGROUND: The deliberate induction of carbon dioxide pneumoperitoneum during laparoscopic surgery could be a possible source of cardiovascular collapse. The effects of elevated intraabdominal pressure (IAP) on systemic hemodynamics and splanchnic blood flow created by insufflation of carbon dioxide were examined in anesthetized dogs. METHODS: Stepwise increases in IAP of 8 (n = 7), 12 (n = 7), and 16 (n = 7) mm Hg were applied to determine the threshold pressure that had minimum influence on these hemodynamics. Hemodynamic parameters were measured at baseline and 1, 2, and 3 hours after the start of insufflation. RESULTS: At an IAP of 16 mm Hg, cardiac output was decreased significantly by 1 hour after the start of insufflation and became progressively lower during the procedure. Systemic vascular resistance was elevated significantly in parallel with the change in cardiac output. Although hepatic arterial blood flow was not decreased significantly, portal venous and superior mesenteric arterial blood flows were diminished significantly at 16 mm Hg, resulting in a decrease in total hepatic blood flow. No significant changes were observed in these parameters at 8 or 12 mm Hg. CONCLUSIONS: Based on these results, an IAP from 8 to 12 mm Hg is recommended for laparoscopic surgery, to avoid complications caused by hemodynamic derangements.

Why it matters

OpenAlex reports 71 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The deliberate induction of carbon dioxide pneumoperitoneum during laparoscopic surgery could be a possible source of cardiovascular collapse. The effects of elevated intraabdominal pressure (IAP) on systemic hemodynamics and splanchnic blood flow created by insufflation of carbon dioxide were examined in anesthetized dogs. METHODS: Stepwise increases in IAP of 8 (n = 7), 12 (n = 7), and 16 (n = 7) mm Hg were applied to determine the threshold pressure that had minimum influence on these hemodynamics. Hemodynamic parameters were measured at baseline and 1, 2, and 3 hours after the start of insufflation. RESULTS: At an IAP of 16 mm Hg, cardiac output was decreased significantly by 1 hour after the start of insufflation and became progressively lower during the procedure. Systemic vascular resistance was elevated significantly in parallel with the change in cardiac output. Although hepatic arterial blood flow was not decreased significantly, portal venous and superior mesenteric arterial blood flows were diminished significantly at 16 mm Hg, resulting in a decrease in total hepatic blood flow. No significant changes were observed in these parameters at 8 or 12 mm Hg. CONCLUSIONS: Based on these results, an IAP from 8 to 12 mm Hg is recommended for laparoscopic surgery, to avoid complications caused by hemodynamic derangements.

Key concepts: Pneumoperitoneum, Medicine, Insufflation, Hemodynamics, Splanchnic, Anesthesia, Cardiac output, Vascular resistance

Related papers

Back to paper searchBrowse research topicsOriginal source
Safe intraabdominal pressure of carbon dioxide pneumoperitoneum during laparoscopic surgery. — Research Paper | ScholarLens