2015•EngineeringOpen access

Performance of a Large-Scale Medical Waste Incinerator in a Referral Hospital

Veilla E. Matee, Samwel Victor Manyele

Open full text 9 citations

Abstract

The aim of the study was to analyze the performance of large scale incinerator installed in a referral hospital. The study involved weighing and loading infectious waste of different composition (sharps and other waste), recording temperatures in the primary and secondary chamber with time, fuel used and collecting and weighing the bottom ash for 65 days. The analysis shows that the incinerator on average uses 362 L/day (45 L/h) to incinerate 945 kg of medical waste (40.8 kg/day of sharps waste and 904 kg/day of other waste), generating 51.2 kg of ash daily. The observed fuel consumption rate was too high necessitating corrective action. The average weight reduction was 94.6%. The study shows that the average sharps waste composition for medical waste incinerated was 4.3% and other waste was 95.7%. The incinerator capacity ranged between 100 and 130 kg/h. The fuel effectiveness ranged between 2.0 and 3.0 liters of diesel per kg of waste incinerated. The fuel effectiveness increased linearly with total waste incinerated and incinerator capacity, respectively, depending on the fuel consumption rate.

Open-access reader

About this research paper

What this paper is about

The aim of the study was to analyze the performance of large scale incinerator installed in a referral hospital. The study involved weighing and loading infectious waste of different composition (sharps and other waste), recording temperatures in the primary and secondary chamber with time, fuel used and collecting and weighing the bottom ash for 65 days. The analysis shows that the incinerator on average uses 362 L/day (45 L/h) to incinerate 945 kg of medical waste (40.8 kg/day of sharps waste and 904 kg/day of other waste), generating 51.2 kg of ash daily. The observed fuel consumption rate was too high necessitating corrective action. The average weight reduction was 94.6%. The study shows that the average sharps waste composition for medical waste incinerated was 4.3% and other waste was 95.7%. The incinerator capacity ranged between 100 and 130 kg/h. The fuel effectiveness ranged between 2.0 and 3.0 liters of diesel per kg of waste incinerated. The fuel effectiveness increased linearly with total waste incinerated and incinerator capacity, respectively, depending on the fuel consumption rate.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The aim of the study was to analyze the performance of large scale incinerator installed in a referral hospital. The study involved weighing and loading infectious waste of different composition (sharps and other waste), recording temperatures in the primary and secondary chamber with time, fuel used and collecting and weighing the bottom ash for 65 days. The analysis shows that the incinerator on average uses 362 L/day (45 L/h) to incinerate 945 kg of medical waste (40.8 kg/day of sharps waste and 904 kg/day of other waste), generating 51.2 kg of ash daily. The observed fuel consumption rate was too high necessitating corrective action. The average weight reduction was 94.6%. The study shows that the average sharps waste composition for medical waste incinerated was 4.3% and other waste was 95.7%. The incinerator capacity ranged between 100 and 130 kg/h. The fuel effectiveness ranged between 2.0 and 3.0 liters of diesel per kg of waste incinerated. The fuel effectiveness increased linearly with total waste incinerated and incinerator capacity, respectively, depending on the fuel consumption rate.

Key concepts: Incineration, Medical waste, Hospital waste, Waste management, Environmental science, Fuel efficiency, Medicine, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance of a Large-Scale Medical Waste Incinerator in a Referral Hospital — Research Paper | ScholarLens