INITIAL CALIBRATION RESULTS FROM THE AEDC-PWT 4-FOOT TRANSONIC TUNNEL

SIR C HARTLEY, J. L. Jacocks

Open publisher page 0 citations

Abstract

Abstract : Tests were conducted in the AEDC Aerodynamic Wind Tunnel, Transonic (4T), to determine the tunnel calibration, Mach number distributions, and boundary-layer thicknesses. During the tests, Mach number was varied from 0.1 to 1.4, test section wall angle from -0.5 to 0.5 deg, and test section wall porosity from 0 to 10 percent. Data were obtained at various stagnation pressure levels from 500 to 2500 psf. Considerable development of the flow expansion region was required to obtain uniform supersonic Mach number distributions. Good Mach number distributions are obtainable up to and including Mach number 1.2. The distributions from Mach number 1.25 to 1.4 are suitable only for very limited testing. The results show that the tunnel calibration is a function of test section wall porosity and wall angle. Boundary-layer thicknesses on the contoured walls and parallel walls at the nozzle exit are nearly equal.

About this research paper

What this paper is about

Abstract : Tests were conducted in the AEDC Aerodynamic Wind Tunnel, Transonic (4T), to determine the tunnel calibration, Mach number distributions, and boundary-layer thicknesses. During the tests, Mach number was varied from 0.1 to 1.4, test section wall angle from -0.5 to 0.5 deg, and test section wall porosity from 0 to 10 percent. Data were obtained at various stagnation pressure levels from 500 to 2500 psf. Considerable development of the flow expansion region was required to obtain uniform supersonic Mach number distributions. Good Mach number distributions are obtainable up to and including Mach number 1.2. The distributions from Mach number 1.25 to 1.4 are suitable only for very limited testing. The results show that the tunnel calibration is a function of test section wall porosity and wall angle. Boundary-layer thicknesses on the contoured walls and parallel walls at the nozzle exit are nearly equal.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract : Tests were conducted in the AEDC Aerodynamic Wind Tunnel, Transonic (4T), to determine the tunnel calibration, Mach number distributions, and boundary-layer thicknesses. During the tests, Mach number was varied from 0.1 to 1.4, test section wall angle from -0.5 to 0.5 deg, and test section wall porosity from 0 to 10 percent. Data were obtained at various stagnation pressure levels from 500 to 2500 psf. Considerable development of the flow expansion region was required to obtain uniform supersonic Mach number distributions. Good Mach number distributions are obtainable up to and including Mach number 1.2. The distributions from Mach number 1.25 to 1.4 are suitable only for very limited testing. The results show that the tunnel calibration is a function of test section wall porosity and wall angle. Boundary-layer thicknesses on the contoured walls and parallel walls at the nozzle exit are nearly equal.

Key concepts: Transonic, Geology, Calibration, Geodesy, Physics, Mechanics, Aerodynamics, Quantum mechanics

Related papers

Back to paper searchBrowse research topicsOriginal source
INITIAL CALIBRATION RESULTS FROM THE AEDC-PWT 4-FOOT TRANSONIC TUNNEL — Research Paper | ScholarLens