2012•Artificial OrgansRequires access

Do Hemodialysis Adequacy Data Reflect Reality?

Şükrü Ulusoy, Erdal Güngör, Semih Gül, Gülsüm Özkan, Süleyman Caner Karahan, Dede Şit, İbrahim Akdağ, Cevat Topal, Adnan Yavuz, Kübra Kaynar, Ömer Bıçak, İsmail Bayraktutan, Seyit Hisoğlu

Open publisher page 2 citations

Abstract

Hemodialysis (HD) adequacy requires monitoring in line with standards and at appropriate intervals. However, the use of inappropriate or incorrectly applied techniques in the determination of HD adequacy can lead to highly unfortunate results. This study was intended to identify the path to a solution by determining how far HD adequacy in HD centers in our region reflects reality. Three hundred and thirty HD patients from eight centers were included. On the first visit, predialysis and postdialysis blood collection with the centers' own methods being used were observed and errors were recorded. Kt/V1 was calculated from pre- and postdialysis blood specimens taken by the units themselves. On the second visit, one session later, pre- and postdialysis blood samples were collected in line with guidelines by ourselves, the authors, and Kt/V2 was calculated from these samples. The eight units' total Kt/V2 value was significantly lower compared with Kt/V1 (<0.0001). The level of patients in all centers with Kt/V1 <1.2 was 13.5%, and that of patients with Kt/V2 <1.2 was 22.1%. No center, apart from one unit, managed to complete the collection of blood specimens as recommended by the guidelines. With one exception, blood collection for HD adequacy was not performed using proper technique in any center. This simple but easily overlooked situation, HD being regarded as adequate though in fact it is not, may lead to patients not being treated effectively and accurately and to a rise in mortality and morbidity in the long term.

About this research paper

What this paper is about

Hemodialysis (HD) adequacy requires monitoring in line with standards and at appropriate intervals. However, the use of inappropriate or incorrectly applied techniques in the determination of HD adequacy can lead to highly unfortunate results. This study was intended to identify the path to a solution by determining how far HD adequacy in HD centers in our region reflects reality. Three hundred and thirty HD patients from eight centers were included. On the first visit, predialysis and postdialysis blood collection with the centers' own methods being used were observed and errors were recorded. Kt/V1 was calculated from pre- and postdialysis blood specimens taken by the units themselves. On the second visit, one session later, pre- and postdialysis blood samples were collected in line with guidelines by ourselves, the authors, and Kt/V2 was calculated from these samples. The eight units' total Kt/V2 value was significantly lower compared with Kt/V1 (<0.0001). The level of patients in all centers with Kt/V1 <1.2 was 13.5%, and that of patients with Kt/V2 <1.2 was 22.1%. No center, apart from one unit, managed to complete the collection of blood specimens as recommended by the guidelines. With one exception, blood collection for HD adequacy was not performed using proper technique in any center. This simple but easily overlooked situation, HD being regarded as adequate though in fact it is not, may lead to patients not being treated effectively and accurately and to a rise in mortality and morbidity in the long term.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Hemodialysis (HD) adequacy requires monitoring in line with standards and at appropriate intervals. However, the use of inappropriate or incorrectly applied techniques in the determination of HD adequacy can lead to highly unfortunate results. This study was intended to identify the path to a solution by determining how far HD adequacy in HD centers in our region reflects reality. Three hundred and thirty HD patients from eight centers were included. On the first visit, predialysis and postdialysis blood collection with the centers' own methods being used were observed and errors were recorded. Kt/V1 was calculated from pre- and postdialysis blood specimens taken by the units themselves. On the second visit, one session later, pre- and postdialysis blood samples were collected in line with guidelines by ourselves, the authors, and Kt/V2 was calculated from these samples. The eight units' total Kt/V2 value was significantly lower compared with Kt/V1 (<0.0001). The level of patients in all centers with Kt/V1 <1.2 was 13.5%, and that of patients with Kt/V2 <1.2 was 22.1%. No center, apart from one unit, managed to complete the collection of blood specimens as recommended by the guidelines. With one exception, blood collection for HD adequacy was not performed using proper technique in any center. This simple but easily overlooked situation, HD being regarded as adequate though in fact it is not, may lead to patients not being treated effectively and accurately and to a rise in mortality and morbidity in the long term.

Key concepts: Hemodialysis, Medicine, Blood collection, Emergency medicine, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Do Hemodialysis Adequacy Data Reflect Reality? — Research Paper | ScholarLens