Reproducibility of measuring amniotic fluid index and single deepest vertical pool throughout gestation
Joyce Sande, C. Ioannou, Ippokratis Sarris, Eric O. Ohuma, Aris T. Papageorghiou
Abstract
Joyce Sande, C. Ioannou, Ippokratis Sarris, Eric O. Ohuma, Aris T. Papageorghiou
Abstract
OBJECTIVE: The aim of this study is to assess the intraobserver and interobserver reproducibility of measurement of amniotic fluid index (AFI) and single deepest vertical pool (SDVP), also known as the maximal vertical pocket. METHODS: A total of 175 fetuses were evaluated. For each fetus, two observers acquired duplicate sets of AFI and SDVP. Measurement differences were expressed as actual and percentage values. For all comparisons, Bland-Altman plots were used to compare differences, and limits of agreement were calculated. RESULTS: Intraobserver and interobserver agreement remained fairly constant with gestation, both for AFI and SDVP. The intraobserver limits of agreement for AFI were -5.2 to 5 cm or -39% to 37%; whereas for SDVP, these were -2.6 to 2.4 cm or -52% to 48%. The interobserver limits of agreement for AFI measurement were -7.3 to 7.1 cm or -54% to 53% and for SDVP measurement were -2.5 to 2.5 cm or -51% to 52%. Intraobserver coefficient of variation for SDVP was 14% and for AFI was 19%; the interobserver coefficient was 19% for both AFI and SDVP. CONCLUSION: Limits of agreement for both methods are wide. The choice of method should be dictated by clinical considerations other than method reproducibility.
OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: The aim of this study is to assess the intraobserver and interobserver reproducibility of measurement of amniotic fluid index (AFI) and single deepest vertical pool (SDVP), also known as the maximal vertical pocket. METHODS: A total of 175 fetuses were evaluated. For each fetus, two observers acquired duplicate sets of AFI and SDVP. Measurement differences were expressed as actual and percentage values. For all comparisons, Bland-Altman plots were used to compare differences, and limits of agreement were calculated. RESULTS: Intraobserver and interobserver agreement remained fairly constant with gestation, both for AFI and SDVP. The intraobserver limits of agreement for AFI were -5.2 to 5 cm or -39% to 37%; whereas for SDVP, these were -2.6 to 2.4 cm or -52% to 48%. The interobserver limits of agreement for AFI measurement were -7.3 to 7.1 cm or -54% to 53% and for SDVP measurement were -2.5 to 2.5 cm or -51% to 52%. Intraobserver coefficient of variation for SDVP was 14% and for AFI was 19%; the interobserver coefficient was 19% for both AFI and SDVP. CONCLUSION: Limits of agreement for both methods are wide. The choice of method should be dictated by clinical considerations other than method reproducibility.
Key concepts: Reproducibility, Limits of agreement, Coefficient of variation, Amniotic fluid, Medicine, Nuclear medicine, Amniotic fluid index, Gestation