2001•Applied OpticsRequires access

High-power continuous-wave Cr^4+:forsterite laser

Anatoliy A Ivanov, Vladislav I. Shcheslavskiy, Vladislav V. Yakovlev, B. I. Minkov, Alexander Vasiliev

Open publisher page 3 citations

Abstract

The temperature and pump power dependence of infrared luminescence of Cr(4+):forsterite are measured. It is demonstrated that temperature-dependent fluorescence in Cr(4+):forsterite is the major reason for saturation of the output power of a continuous-wave laser. At higher pump intensities the temperature rise inside the crystal becomes significant, and even outside cooling does not help to prevent significant reduction of the laser performance. These measurements serve as a guideline to construct a high-power continuous-wave Cr(4+):forsterite laser.

About this research paper

What this paper is about

The temperature and pump power dependence of infrared luminescence of Cr(4+):forsterite are measured. It is demonstrated that temperature-dependent fluorescence in Cr(4+):forsterite is the major reason for saturation of the output power of a continuous-wave laser. At higher pump intensities the temperature rise inside the crystal becomes significant, and even outside cooling does not help to prevent significant reduction of the laser performance. These measurements serve as a guideline to construct a high-power continuous-wave Cr(4+):forsterite laser.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The temperature and pump power dependence of infrared luminescence of Cr(4+):forsterite are measured. It is demonstrated that temperature-dependent fluorescence in Cr(4+):forsterite is the major reason for saturation of the output power of a continuous-wave laser. At higher pump intensities the temperature rise inside the crystal becomes significant, and even outside cooling does not help to prevent significant reduction of the laser performance. These measurements serve as a guideline to construct a high-power continuous-wave Cr(4+):forsterite laser.

Key concepts: Forsterite, Continuous wave, Materials science, Optics, Laser, Laser power scaling, Infrared, Optoelectronics

Related papers

Back to paper searchBrowse research topicsOriginal source
High-power continuous-wave Cr^4+:forsterite laser — Research Paper | ScholarLens