2015British Journal of RadiologyOpen access

Variation in patient position and impact on carbon-ion scanning beam distribution during prostate treatment

Shinichiro Mori, Taku Inaniwa, K. Miki, Katsuyuki Tanimoto, Minoru Tajiri, Daigo Kuroiwa, Minoru Nakao, Yurika Shiraishi, Kouichi Shibayama, Hiroshi Tsuji

Open full text 1 citations

Abstract

OBJECTIVE: We assessed the impact of changes in patient position on carbon-ion scanning beam distribution during treatment for prostate cancer. METHODS: 68 patients were selected. Carbon-ion scanning dose was calculated. Two different planning target volumes (PTVs) were defined: PTV1 was the clinical target volume plus a set-up margin for the anterior/lateral sides and posterior side, while PTV2 was the same as PTV1 minus the posterior side. Total prescribed doses of 34.4 Gy [relative biological effectiveness (RBE)] and 17.2 Gy (RBE) were given to PTV1 and PTV2, respectively. To estimate the influence of geometric variations on dose distribution, the dose was recalculated on the rigidly shifted single planning CT based on two dimensional-three dimensional rigid registration of the orthogonal radiographs before and after treatment for the fraction of maximum positional changes. RESULTS: Intrafractional patient positional change values averaged over all patients throughout the treatment course were less than the target registration error = 2.00 mm and angular error = 1.27°. However, these maximum positional errors did not occur in all 12 treatment fractions. Even though large positional changes occurred during irradiation in all treatment fractions, lowest dose encompassing 95% of the target (D95)-PTV1 was >98% of the prescribed dose. CONCLUSION: Intrafractional patient positional changes occurred during treatment beam irradiation and degraded carbon-ion beam dose distribution. Our evaluation did not consider non-rigid deformations, however, dose distribution was still within clinically acceptable levels. ADVANCES IN KNOWLEDGE: Inter- and intrafractional changes did not affect carbon-ion beam prostate treatment accuracy.

About this research paper

What this paper is about

OBJECTIVE: We assessed the impact of changes in patient position on carbon-ion scanning beam distribution during treatment for prostate cancer. METHODS: 68 patients were selected. Carbon-ion scanning dose was calculated. Two different planning target volumes (PTVs) were defined: PTV1 was the clinical target volume plus a set-up margin for the anterior/lateral sides and posterior side, while PTV2 was the same as PTV1 minus the posterior side. Total prescribed doses of 34.4 Gy [relative biological effectiveness (RBE)] and 17.2 Gy (RBE) were given to PTV1 and PTV2, respectively. To estimate the influence of geometric variations on dose distribution, the dose was recalculated on the rigidly shifted single planning CT based on two dimensional-three dimensional rigid registration of the orthogonal radiographs before and after treatment for the fraction of maximum positional changes. RESULTS: Intrafractional patient positional change values averaged over all patients throughout the treatment course were less than the target registration error = 2.00 mm and angular error = 1.27°. However, these maximum positional errors did not occur in all 12 treatment fractions. Even though large positional changes occurred during irradiation in all treatment fractions, lowest dose encompassing 95% of the target (D95)-PTV1 was >98% of the prescribed dose. CONCLUSION: Intrafractional patient positional changes occurred during treatment beam irradiation and degraded carbon-ion beam dose distribution. Our evaluation did not consider non-rigid deformations, however, dose distribution was still within clinically acceptable levels. ADVANCES IN KNOWLEDGE: Inter- and intrafractional changes did not affect carbon-ion beam prostate treatment accuracy.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: We assessed the impact of changes in patient position on carbon-ion scanning beam distribution during treatment for prostate cancer. METHODS: 68 patients were selected. Carbon-ion scanning dose was calculated. Two different planning target volumes (PTVs) were defined: PTV1 was the clinical target volume plus a set-up margin for the anterior/lateral sides and posterior side, while PTV2 was the same as PTV1 minus the posterior side. Total prescribed doses of 34.4 Gy [relative biological effectiveness (RBE)] and 17.2 Gy (RBE) were given to PTV1 and PTV2, respectively. To estimate the influence of geometric variations on dose distribution, the dose was recalculated on the rigidly shifted single planning CT based on two dimensional-three dimensional rigid registration of the orthogonal radiographs before and after treatment for the fraction of maximum positional changes. RESULTS: Intrafractional patient positional change values averaged over all patients throughout the treatment course were less than the target registration error = 2.00 mm and angular error = 1.27°. However, these maximum positional errors did not occur in all 12 treatment fractions. Even though large positional changes occurred during irradiation in all treatment fractions, lowest dose encompassing 95% of the target (D95)-PTV1 was >98% of the prescribed dose. CONCLUSION: Intrafractional patient positional changes occurred during treatment beam irradiation and degraded carbon-ion beam dose distribution. Our evaluation did not consider non-rigid deformations, however, dose distribution was still within clinically acceptable levels. ADVANCES IN KNOWLEDGE: Inter- and intrafractional changes did not affect carbon-ion beam prostate treatment accuracy.

Key concepts: Nuclear medicine, Medicine, Radiation treatment planning, Prostate, Radiation therapy, Prostate cancer, Carbon Ion Radiotherapy, Irradiation

Related papers

Back to paper searchBrowse research topicsOriginal source
Variation in patient position and impact on carbon-ion scanning beam distribution during prostate treatment — Research Paper | ScholarLens