1998PubMedRequires access

[The influence of RS-Timolol in comparison with R-Timolol and S-Timolol on the intraocular pressure in water-loaded rabbits].

Krystyna Czechowicz-Janicka, Ewa Kamińska, Julia Staszkiewicz, Barbara Terelak-Borys, K Oledzka, A Danysz

Open publisher page 1 citations

Abstract

PURPOSE: It is assumed that S-timolol can produce more severe systemic adverse reactions than R-timolol. The aim of this study was to estimate the intraocular pressure-lowering effect of RS-timolol in comparison to R-timolol and S-timolol in water-loaded rabbits. MATERIAL AND METHODS: Ocular hypertension was provoked in rabbits by orogastric water loading. Topical administration of one of three timolol solutions: 0.85%, RS-timolol, or 3% R-timolol, or 0.5% S-timolol was performed to the right eyes 40 min before starting the water loading procedure. Left eyes served as a control group. Intraocular pressure was measured before and 30, 60, 90, 120 min after the water loading. RESULTS: Intraocular pressure-lowering effect of all three timolol solutions was comparable. CONCLUSION: RS-timolol can be effective for lowering intraocular pressure in rabbits.

About this research paper

What this paper is about

PURPOSE: It is assumed that S-timolol can produce more severe systemic adverse reactions than R-timolol. The aim of this study was to estimate the intraocular pressure-lowering effect of RS-timolol in comparison to R-timolol and S-timolol in water-loaded rabbits. MATERIAL AND METHODS: Ocular hypertension was provoked in rabbits by orogastric water loading. Topical administration of one of three timolol solutions: 0.85%, RS-timolol, or 3% R-timolol, or 0.5% S-timolol was performed to the right eyes 40 min before starting the water loading procedure. Left eyes served as a control group. Intraocular pressure was measured before and 30, 60, 90, 120 min after the water loading. RESULTS: Intraocular pressure-lowering effect of all three timolol solutions was comparable. CONCLUSION: RS-timolol can be effective for lowering intraocular pressure in rabbits.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: It is assumed that S-timolol can produce more severe systemic adverse reactions than R-timolol. The aim of this study was to estimate the intraocular pressure-lowering effect of RS-timolol in comparison to R-timolol and S-timolol in water-loaded rabbits. MATERIAL AND METHODS: Ocular hypertension was provoked in rabbits by orogastric water loading. Topical administration of one of three timolol solutions: 0.85%, RS-timolol, or 3% R-timolol, or 0.5% S-timolol was performed to the right eyes 40 min before starting the water loading procedure. Left eyes served as a control group. Intraocular pressure was measured before and 30, 60, 90, 120 min after the water loading. RESULTS: Intraocular pressure-lowering effect of all three timolol solutions was comparable. CONCLUSION: RS-timolol can be effective for lowering intraocular pressure in rabbits.

Key concepts: Timolol, Intraocular pressure, Medicine, Ocular hypertension, Ophthalmology, Anesthesia

Related papers

Back to paper searchBrowse research topicsOriginal source
[The influence of RS-Timolol in comparison with R-Timolol and S-Timolol on the intraocular pressure in water-loaded rabbits]. — Research Paper | ScholarLens