1978•Clinical ChemistryRequires access

Enzyme immunoassay and gas--liquid chromatography compared for determination of lidocaine in serum.

Brian E. Pape, Richard C. Whiting, Kayla Parker, Robi David Mitra

Open publisher page 20 citations

Abstract

Lidocaine, an anti-arrhythmic drug, was quantitated in serum by a commercially supplied enzyme immunoassay procedure. Replicate analyses of serum controls resulted in a within-assay coefficient of variation of less than 5.0 and a between-assay coefficient of variation of less than 6.5. Regression analysis of 87 serum samples analyzed by this technique (y) and by gas-liquid chromatography (x) gave the equation y = 0.96x - 0.03 (r = 0.99). Clinical evaluation of the results indicates the enzyme immunoassay technique to be highly specific and sensitive for lidocaine.

About this research paper

What this paper is about

Lidocaine, an anti-arrhythmic drug, was quantitated in serum by a commercially supplied enzyme immunoassay procedure. Replicate analyses of serum controls resulted in a within-assay coefficient of variation of less than 5.0 and a between-assay coefficient of variation of less than 6.5. Regression analysis of 87 serum samples analyzed by this technique (y) and by gas-liquid chromatography (x) gave the equation y = 0.96x - 0.03 (r = 0.99). Clinical evaluation of the results indicates the enzyme immunoassay technique to be highly specific and sensitive for lidocaine.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Lidocaine, an anti-arrhythmic drug, was quantitated in serum by a commercially supplied enzyme immunoassay procedure. Replicate analyses of serum controls resulted in a within-assay coefficient of variation of less than 5.0 and a between-assay coefficient of variation of less than 6.5. Regression analysis of 87 serum samples analyzed by this technique (y) and by gas-liquid chromatography (x) gave the equation y = 0.96x - 0.03 (r = 0.99). Clinical evaluation of the results indicates the enzyme immunoassay technique to be highly specific and sensitive for lidocaine.

Key concepts: Immunoassay, Chromatography, Lidocaine, Chemistry, Coefficient of variation, Gas chromatography, Enzyme, Antibody

Related papers

Back to paper searchBrowse research topicsOriginal source
Enzyme immunoassay and gas--liquid chromatography compared for determination of lidocaine in serum. — Research Paper | ScholarLens