2008Acta Anaesthesiologica ScandinavicaRequires access

Performance of electrical impedance tomography in detecting regional tidal volumes during one‐lung ventilation

Sven Pulletz, Gunnar Elke, Günther Zick, Dirk Schädler, Jens Scholz, N. Weiler, Inéz Frerichs

Open publisher page 34 citations

Abstract

BACKGROUND: Electrical impedance tomography (EIT) is becoming a new medical imaging modality for continuous monitoring of regional lung function in the intensive care unit or operating room. The aim of our study was to evaluate the performance of EIT in detecting regional tidal volumes in patients during volume-controlled mechanical ventilation of one or both lungs. METHODS: Ten adult patients undergoing elective thoracic surgery were included. EIT measurements were performed with the Goe-MF II EIT system. Data were collected before surgery during ventilation of both, the right and left lungs. Tidal volumes of 800 and 400 ml were applied during bilateral and unilateral ventilation, respectively. RESULTS: Ventilation-related impedance changes determined in the whole chest cross-section during the right and left lung ventilation did not significantly differ from each other and were equal to 47.6+/-5.6% and 48.5+/-7.8% (mean+/-SD) of the value determined during bilateral ventilation. During unilateral ventilation, EIT clearly separated the ventilated and non-ventilated lung regions; nevertheless, ventilation-related impedance changes were also detected at the non-ventilated sides in areas corresponding to 3.4+/-4.1% and 12.4+/-6.9% of the scan halves during ventilation of the left and right lung, respectively. Changes in global tidal volumes were adequately detected by EIT during both bilateral and unilateral lung ventilation. CONCLUSION: Although good separation of the ventilated and non-ventilated sides of the chest was possible, the data indicate that reliable quantification of regional tidal volumes during asymmetric or inhomogeneous distribution patterns requires regions-of-interest analysis.

About this research paper

What this paper is about

BACKGROUND: Electrical impedance tomography (EIT) is becoming a new medical imaging modality for continuous monitoring of regional lung function in the intensive care unit or operating room. The aim of our study was to evaluate the performance of EIT in detecting regional tidal volumes in patients during volume-controlled mechanical ventilation of one or both lungs. METHODS: Ten adult patients undergoing elective thoracic surgery were included. EIT measurements were performed with the Goe-MF II EIT system. Data were collected before surgery during ventilation of both, the right and left lungs. Tidal volumes of 800 and 400 ml were applied during bilateral and unilateral ventilation, respectively. RESULTS: Ventilation-related impedance changes determined in the whole chest cross-section during the right and left lung ventilation did not significantly differ from each other and were equal to 47.6+/-5.6% and 48.5+/-7.8% (mean+/-SD) of the value determined during bilateral ventilation. During unilateral ventilation, EIT clearly separated the ventilated and non-ventilated lung regions; nevertheless, ventilation-related impedance changes were also detected at the non-ventilated sides in areas corresponding to 3.4+/-4.1% and 12.4+/-6.9% of the scan halves during ventilation of the left and right lung, respectively. Changes in global tidal volumes were adequately detected by EIT during both bilateral and unilateral lung ventilation. CONCLUSION: Although good separation of the ventilated and non-ventilated sides of the chest was possible, the data indicate that reliable quantification of regional tidal volumes during asymmetric or inhomogeneous distribution patterns requires regions-of-interest analysis.

Why it matters

OpenAlex reports 34 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Electrical impedance tomography (EIT) is becoming a new medical imaging modality for continuous monitoring of regional lung function in the intensive care unit or operating room. The aim of our study was to evaluate the performance of EIT in detecting regional tidal volumes in patients during volume-controlled mechanical ventilation of one or both lungs. METHODS: Ten adult patients undergoing elective thoracic surgery were included. EIT measurements were performed with the Goe-MF II EIT system. Data were collected before surgery during ventilation of both, the right and left lungs. Tidal volumes of 800 and 400 ml were applied during bilateral and unilateral ventilation, respectively. RESULTS: Ventilation-related impedance changes determined in the whole chest cross-section during the right and left lung ventilation did not significantly differ from each other and were equal to 47.6+/-5.6% and 48.5+/-7.8% (mean+/-SD) of the value determined during bilateral ventilation. During unilateral ventilation, EIT clearly separated the ventilated and non-ventilated lung regions; nevertheless, ventilation-related impedance changes were also detected at the non-ventilated sides in areas corresponding to 3.4+/-4.1% and 12.4+/-6.9% of the scan halves during ventilation of the left and right lung, respectively. Changes in global tidal volumes were adequately detected by EIT during both bilateral and unilateral lung ventilation. CONCLUSION: Although good separation of the ventilated and non-ventilated sides of the chest was possible, the data indicate that reliable quantification of regional tidal volumes during asymmetric or inhomogeneous distribution patterns requires regions-of-interest analysis.

Key concepts: Electrical impedance tomography, Medicine, Ventilation (architecture), Tidal volume, Lung, Mechanical ventilation, Intensive care, Lung ventilation

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance of electrical impedance tomography in detecting regional tidal volumes during one‐lung ventilation — Research Paper | ScholarLens