2014Journal of Veterinary Emergency and Critical CareRequires access

Evaluation of a point‐of‐care anticoagulant rodenticide test for dogs

Stephanie A. Istvan, Steven L. Marks, Lisa A. Murphy, David C. Dorman

Open publisher page 13 citations

Abstract

OBJECTIVE: To evaluate a point-of-care anticoagulant rodenticide lateral flow analyzer for the detection of various rodenticide compounds. DESIGN: Prospective, laboratory study. SETTING: University teaching hospital. ANIMALS: The study utilized a serum sample from one healthy canine donor. Samples were centrifuged and serum samples were aliquoted and either used within 4 hours or frozen at -70°C for further quantitative analysis. INTERVENTIONS: Samples were spiked with clinically relevant concentrations of 1 of 6 rodenticide compounds (warfarin, pindone, chlorphacinone, brodifacoum, bromethalin, and its metabolite desmethylbromethalin). Seventy-five microliters of spiked serum (or unaltered serum) was introduced into the lateral flow test. MEASUREMENTS AND MAIN RESULTS: Three readers who were blinded to the sample preparation interpreted the lateral flow test as either positive or negative for the presence of anticoagulant rodenticide. All readers were in agreement for the results of each serum sample. The point-of-care test kit was able to detect a single anticoagulant rodenticide (warfarin) at concentrations below the manufacturer's recommended limit of detection, but was unable to detect any other anticoagulant rodenticide. CONCLUSIONS: The results of this test and therapeutic interventions must be considered in light of history, physical examination, and other clinical data. Based on results from this study, the test kit only detects warfarin and not other more common second-generation anticoagulant rodenticides.

About this research paper

What this paper is about

OBJECTIVE: To evaluate a point-of-care anticoagulant rodenticide lateral flow analyzer for the detection of various rodenticide compounds. DESIGN: Prospective, laboratory study. SETTING: University teaching hospital. ANIMALS: The study utilized a serum sample from one healthy canine donor. Samples were centrifuged and serum samples were aliquoted and either used within 4 hours or frozen at -70°C for further quantitative analysis. INTERVENTIONS: Samples were spiked with clinically relevant concentrations of 1 of 6 rodenticide compounds (warfarin, pindone, chlorphacinone, brodifacoum, bromethalin, and its metabolite desmethylbromethalin). Seventy-five microliters of spiked serum (or unaltered serum) was introduced into the lateral flow test. MEASUREMENTS AND MAIN RESULTS: Three readers who were blinded to the sample preparation interpreted the lateral flow test as either positive or negative for the presence of anticoagulant rodenticide. All readers were in agreement for the results of each serum sample. The point-of-care test kit was able to detect a single anticoagulant rodenticide (warfarin) at concentrations below the manufacturer's recommended limit of detection, but was unable to detect any other anticoagulant rodenticide. CONCLUSIONS: The results of this test and therapeutic interventions must be considered in light of history, physical examination, and other clinical data. Based on results from this study, the test kit only detects warfarin and not other more common second-generation anticoagulant rodenticides.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To evaluate a point-of-care anticoagulant rodenticide lateral flow analyzer for the detection of various rodenticide compounds. DESIGN: Prospective, laboratory study. SETTING: University teaching hospital. ANIMALS: The study utilized a serum sample from one healthy canine donor. Samples were centrifuged and serum samples were aliquoted and either used within 4 hours or frozen at -70°C for further quantitative analysis. INTERVENTIONS: Samples were spiked with clinically relevant concentrations of 1 of 6 rodenticide compounds (warfarin, pindone, chlorphacinone, brodifacoum, bromethalin, and its metabolite desmethylbromethalin). Seventy-five microliters of spiked serum (or unaltered serum) was introduced into the lateral flow test. MEASUREMENTS AND MAIN RESULTS: Three readers who were blinded to the sample preparation interpreted the lateral flow test as either positive or negative for the presence of anticoagulant rodenticide. All readers were in agreement for the results of each serum sample. The point-of-care test kit was able to detect a single anticoagulant rodenticide (warfarin) at concentrations below the manufacturer's recommended limit of detection, but was unable to detect any other anticoagulant rodenticide. CONCLUSIONS: The results of this test and therapeutic interventions must be considered in light of history, physical examination, and other clinical data. Based on results from this study, the test kit only detects warfarin and not other more common second-generation anticoagulant rodenticides.

Key concepts: Rodenticide, Brodifacoum, Medicine, Anticoagulant, Warfarin, Point of care, Toxicology, Anesthesia

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of a point‐of‐care anticoagulant rodenticide test for dogs — Research Paper | ScholarLens