2008•Infoscience (Ecole Polytechnique Fédérale de Lausanne)Open access

INFLUENCE OF THE SATURATION TEMPERATURE ON THE HEAT TRANSFER COEFFICIENT FOR FLOW BOILING INSIDE HORIZONTAL SMOOTH TUBES

Ricardo J. da Silva Lima, Ênio Pedone Bandarra Filho, John Richard Thome

Open full text 0 citations

Abstract

This article presents experimental results of heat transfer from two different studies [1, 2] for horizontal flow boiling inside smooth copper tubes with different refrigerants. The main goal of this study was to verify the influence of the saturation temperature on the heat transfer coefficient. The experimental tests were carried for refrigerants R-134a, R-22 and R-404A, at saturation temperatures ranging from 5 to 20°C for two tubes of 12.7 and 13.84 mm ID and three heat fluxes of 5, 7.5 and 17.5 kW/m2. The vapor quality ranged from 5 to 90% and the mass velocity was 300 kg/s.m2. Under these conditions the heat transfer coefficient shows an interesting trend: it behaves differently, in function of the saturation temperature, in the nucleate and convective boiling dominated regions. In the nucleate boiling dominated region the heat transfer coefficient increases with the saturation temperature. In the convective boiling dominated region this phenomenon is inverted, that is, the heat transfer coefficient decreases with the saturation temperature. This phenomenon was verified through the concept of the thermal resistance of the liquid thickness. Since the heat transfer coefficient is proportional to the inverse of the thermal resistance of the liquid film, it increases with decreasing saturation temperature. The transition between nucleate and convective boiling dominated regions, denominated by [1] as a local minimum of the heat transfer coefficient, was also clearly observed with all the refrigerants.

About this research paper

What this paper is about

This article presents experimental results of heat transfer from two different studies [1, 2] for horizontal flow boiling inside smooth copper tubes with different refrigerants. The main goal of this study was to verify the influence of the saturation temperature on the heat transfer coefficient. The experimental tests were carried for refrigerants R-134a, R-22 and R-404A, at saturation temperatures ranging from 5 to 20°C for two tubes of 12.7 and 13.84 mm ID and three heat fluxes of 5, 7.5 and 17.5 kW/m2. The vapor quality ranged from 5 to 90% and the mass velocity was 300 kg/s.m2. Under these conditions the heat transfer coefficient shows an interesting trend: it behaves differently, in function of the saturation temperature, in the nucleate and convective boiling dominated regions. In the nucleate boiling dominated region the heat transfer coefficient increases with the saturation temperature. In the convective boiling dominated region this phenomenon is inverted, that is, the heat transfer coefficient decreases with the saturation temperature. This phenomenon was verified through the concept of the thermal resistance of the liquid thickness. Since the heat transfer coefficient is proportional to the inverse of the thermal resistance of the liquid film, it increases with decreasing saturation temperature. The transition between nucleate and convective boiling dominated regions, denominated by [1] as a local minimum of the heat transfer coefficient, was also clearly observed with all the refrigerants.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This article presents experimental results of heat transfer from two different studies [1, 2] for horizontal flow boiling inside smooth copper tubes with different refrigerants. The main goal of this study was to verify the influence of the saturation temperature on the heat transfer coefficient. The experimental tests were carried for refrigerants R-134a, R-22 and R-404A, at saturation temperatures ranging from 5 to 20°C for two tubes of 12.7 and 13.84 mm ID and three heat fluxes of 5, 7.5 and 17.5 kW/m2. The vapor quality ranged from 5 to 90% and the mass velocity was 300 kg/s.m2. Under these conditions the heat transfer coefficient shows an interesting trend: it behaves differently, in function of the saturation temperature, in the nucleate and convective boiling dominated regions. In the nucleate boiling dominated region the heat transfer coefficient increases with the saturation temperature. In the convective boiling dominated region this phenomenon is inverted, that is, the heat transfer coefficient decreases with the saturation temperature. This phenomenon was verified through the concept of the thermal resistance of the liquid thickness. Since the heat transfer coefficient is proportional to the inverse of the thermal resistance of the liquid film, it increases with decreasing saturation temperature. The transition between nucleate and convective boiling dominated regions, denominated by [1] as a local minimum of the heat transfer coefficient, was also clearly observed with all the refrigerants.

Key concepts: Nucleate boiling, Heat transfer coefficient, Thermodynamics, Boiling point, Saturation (graph theory), Materials science, Boiling, Heat transfer

Related papers

Back to paper searchBrowse research topicsOriginal source
INFLUENCE OF THE SATURATION TEMPERATURE ON THE HEAT TRANSFER COEFFICIENT FOR FLOW BOILING INSIDE HORIZONTAL SMOOTH TUBES — Research Paper | ScholarLens