1998Unpublished venueRequires access

Evaluation of Nebulizer Performance within the ICP-MS Measurement System for Analysis of SRS Radiological Waste Tank Simulated Solutions

V F Jones

Open publisher page 1 citations

Abstract

High level radioactive waste tanks at the Savannah River Site are high in salt content. The average Total Dissolved Solids (TDS) content is approximately 25%. For ICP-MS optimum signal stability and to reduce blockage of nebulizers and sampling orifices, it is usual to limit analyte solutions to a TDS content of nominally < 0.2%. Dilution to this level to reduce the matrix effect may push some analytes of interest below detectable levels. Five commercially available nebulizers were evaluated in a field study as part of the ICP-MS measurement system for their performance in a high salt matrix. The nebulizers surveyed were a meinhard concentric, cross-flow, micro-concentric (MCN), V-groove, and a direct injection nebulizer (DIN). Analytes spiked into non-radioactive diluted salt solutions ranging from nominal 0.25 – 1.0% TDS were repetitively analyzed with the goal of determining stability of response signal and magnitude of any signal loss/suppression resulting from the diluted salt matrix. The cross-flow nebulizer provided the most stable signal for all salt matrices with the smallest signal loss/suppression due to this matrix. The DIN exhibited a serious lack of tolerance for TDS; possibly due to physical de-tuning of the nebulizer efficiency.

About this research paper

What this paper is about

High level radioactive waste tanks at the Savannah River Site are high in salt content. The average Total Dissolved Solids (TDS) content is approximately 25%. For ICP-MS optimum signal stability and to reduce blockage of nebulizers and sampling orifices, it is usual to limit analyte solutions to a TDS content of nominally < 0.2%. Dilution to this level to reduce the matrix effect may push some analytes of interest below detectable levels. Five commercially available nebulizers were evaluated in a field study as part of the ICP-MS measurement system for their performance in a high salt matrix. The nebulizers surveyed were a meinhard concentric, cross-flow, micro-concentric (MCN), V-groove, and a direct injection nebulizer (DIN). Analytes spiked into non-radioactive diluted salt solutions ranging from nominal 0.25 – 1.0% TDS were repetitively analyzed with the goal of determining stability of response signal and magnitude of any signal loss/suppression resulting from the diluted salt matrix. The cross-flow nebulizer provided the most stable signal for all salt matrices with the smallest signal loss/suppression due to this matrix. The DIN exhibited a serious lack of tolerance for TDS; possibly due to physical de-tuning of the nebulizer efficiency.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

High level radioactive waste tanks at the Savannah River Site are high in salt content. The average Total Dissolved Solids (TDS) content is approximately 25%. For ICP-MS optimum signal stability and to reduce blockage of nebulizers and sampling orifices, it is usual to limit analyte solutions to a TDS content of nominally < 0.2%. Dilution to this level to reduce the matrix effect may push some analytes of interest below detectable levels. Five commercially available nebulizers were evaluated in a field study as part of the ICP-MS measurement system for their performance in a high salt matrix. The nebulizers surveyed were a meinhard concentric, cross-flow, micro-concentric (MCN), V-groove, and a direct injection nebulizer (DIN). Analytes spiked into non-radioactive diluted salt solutions ranging from nominal 0.25 – 1.0% TDS were repetitively analyzed with the goal of determining stability of response signal and magnitude of any signal loss/suppression resulting from the diluted salt matrix. The cross-flow nebulizer provided the most stable signal for all salt matrices with the smallest signal loss/suppression due to this matrix. The DIN exhibited a serious lack of tolerance for TDS; possibly due to physical de-tuning of the nebulizer efficiency.

Key concepts: Nebulizer, Radiological weapon, Environmental science, Waste management, Inductively coupled plasma mass spectrometry, Nuclear engineering, Engineering, Radiochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of Nebulizer Performance within the ICP-MS Measurement System for Analysis of SRS Radiological Waste Tank Simulated Solutions — Research Paper | ScholarLens