1989•PubMedRequires access

Technetium-99m HM-PAO-labeled leukocytes in detection of inflammatory lesions: comparison with gallium-67 citrate.

Martti S. Vorne, Irma Soini, Tuomo Lantto, S Paakkinen

Open publisher page 70 citations

Abstract

Forty-three patients with suspected benign, inflammatory, or infectious diseases were imaged with [99mTc]HM-PAO-labeled leukocytes and [67Ga]citrate. Technetium-99m leukocytes showed 22 true-positive, no false-positive, 19 true-negative, and two false-negative findings and [67Ga]citrate 23, 7, 12 and 1, respectively. The sensitivity, specificity, and accuracy values with 99mTc leukocytes were 92%, 100%, and 95%, and with [67Ga]citrate 96%, 63%, and 81%. Technetium-99m leukocyte scintigraphy has a promising future in comparison with [67Ga]citrate because of the ready availability of [99mTc]HM-PAO, the good image quality, more rapid results (within few hours), and the lower radiation exposure to the patient with 99mTc leukocytes. The usefulness of 99mTc leukocytes in chronic osteomyelitis needs further evaluation.

About this research paper

What this paper is about

Forty-three patients with suspected benign, inflammatory, or infectious diseases were imaged with [99mTc]HM-PAO-labeled leukocytes and [67Ga]citrate. Technetium-99m leukocytes showed 22 true-positive, no false-positive, 19 true-negative, and two false-negative findings and [67Ga]citrate 23, 7, 12 and 1, respectively. The sensitivity, specificity, and accuracy values with 99mTc leukocytes were 92%, 100%, and 95%, and with [67Ga]citrate 96%, 63%, and 81%. Technetium-99m leukocyte scintigraphy has a promising future in comparison with [67Ga]citrate because of the ready availability of [99mTc]HM-PAO, the good image quality, more rapid results (within few hours), and the lower radiation exposure to the patient with 99mTc leukocytes. The usefulness of 99mTc leukocytes in chronic osteomyelitis needs further evaluation.

Why it matters

OpenAlex reports 70 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Forty-three patients with suspected benign, inflammatory, or infectious diseases were imaged with [99mTc]HM-PAO-labeled leukocytes and [67Ga]citrate. Technetium-99m leukocytes showed 22 true-positive, no false-positive, 19 true-negative, and two false-negative findings and [67Ga]citrate 23, 7, 12 and 1, respectively. The sensitivity, specificity, and accuracy values with 99mTc leukocytes were 92%, 100%, and 95%, and with [67Ga]citrate 96%, 63%, and 81%. Technetium-99m leukocyte scintigraphy has a promising future in comparison with [67Ga]citrate because of the ready availability of [99mTc]HM-PAO, the good image quality, more rapid results (within few hours), and the lower radiation exposure to the patient with 99mTc leukocytes. The usefulness of 99mTc leukocytes in chronic osteomyelitis needs further evaluation.

Key concepts: Technetium-99m, Scintigraphy, Technetium, Medicine, Isotopes of technetium, Technetium-99, Nuclear medicine, Isotopes of gallium

Related papers

Back to paper searchBrowse research topicsOriginal source
Technetium-99m HM-PAO-labeled leukocytes in detection of inflammatory lesions: comparison with gallium-67 citrate. — Research Paper | ScholarLens