The Use of Interference-Fit Bolts or Bushes and Hole Cold Expansion for Increasing the Fatigue Life of Thick-Section Aluminium Alloy Bolted Joints

Jonathan Mann, A. S. Machin, W. F. Lupson, R. A. Pell

Open publisher page 12 citations

Abstract

The detection of fatigue cracks at bolt holes in the main spar of the Mirage III wing during full-scale fatigue tests led to a requirement for refurbishment procedures to extend the fatigue lives at a number of critical locations. One of these, which is covered by this investigation, was the spar lower front flange. Flight-by-flight fatigue tests have been carried out to determine the relative fatigue performance of aluminum alloy bolted joint specimens of 28 mm thickness incorporating close-fit bolts, interference-fit bolts (0.4%), hold cold-expansion (3%), interference-fit steel bushes (0.3%) and a combination of cold-expansion and interference-fit bushes. Fractographic measurements of crack development from the bores of holes in specimens incorporating close-fit bolts in non cold-expanded (reamed) and cold-expanded holes clearly indicated much slower fatigue crack propagation rates from the cold-expanded holes until the crack length was close to the nominal region of transition from the residual compressive to tensile stress zone around the cold- expanded holes. Fatigue tests on cold-expanded hole specimens at different spectrum scaling factors indicated that, under the loading sequence used, each 10% increase in stress reduced the life to about half that at the lower stress level.

About this research paper

What this paper is about

The detection of fatigue cracks at bolt holes in the main spar of the Mirage III wing during full-scale fatigue tests led to a requirement for refurbishment procedures to extend the fatigue lives at a number of critical locations. One of these, which is covered by this investigation, was the spar lower front flange. Flight-by-flight fatigue tests have been carried out to determine the relative fatigue performance of aluminum alloy bolted joint specimens of 28 mm thickness incorporating close-fit bolts, interference-fit bolts (0.4%), hold cold-expansion (3%), interference-fit steel bushes (0.3%) and a combination of cold-expansion and interference-fit bushes. Fractographic measurements of crack development from the bores of holes in specimens incorporating close-fit bolts in non cold-expanded (reamed) and cold-expanded holes clearly indicated much slower fatigue crack propagation rates from the cold-expanded holes until the crack length was close to the nominal region of transition from the residual compressive to tensile stress zone around the cold- expanded holes. Fatigue tests on cold-expanded hole specimens at different spectrum scaling factors indicated that, under the loading sequence used, each 10% increase in stress reduced the life to about half that at the lower stress level.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The detection of fatigue cracks at bolt holes in the main spar of the Mirage III wing during full-scale fatigue tests led to a requirement for refurbishment procedures to extend the fatigue lives at a number of critical locations. One of these, which is covered by this investigation, was the spar lower front flange. Flight-by-flight fatigue tests have been carried out to determine the relative fatigue performance of aluminum alloy bolted joint specimens of 28 mm thickness incorporating close-fit bolts, interference-fit bolts (0.4%), hold cold-expansion (3%), interference-fit steel bushes (0.3%) and a combination of cold-expansion and interference-fit bushes. Fractographic measurements of crack development from the bores of holes in specimens incorporating close-fit bolts in non cold-expanded (reamed) and cold-expanded holes clearly indicated much slower fatigue crack propagation rates from the cold-expanded holes until the crack length was close to the nominal region of transition from the residual compressive to tensile stress zone around the cold- expanded holes. Fatigue tests on cold-expanded hole specimens at different spectrum scaling factors indicated that, under the loading sequence used, each 10% increase in stress reduced the life to about half that at the lower stress level.

Key concepts: Flange, Materials science, Structural engineering, Ultimate tensile strength, Aluminium alloy, Stress concentration, Interference fit, Stress (linguistics)

Related papers

Back to paper searchBrowse research topicsOriginal source
The Use of Interference-Fit Bolts or Bushes and Hole Cold Expansion for Increasing the Fatigue Life of Thick-Section Aluminium Alloy Bolted Joints — Research Paper | ScholarLens